Journal Article PUBDB-2024-06448

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
A comparison of deep learning segmentation models for synchrotron radiation based tomograms of biodegradable bone implants

 ;  ;  ;  ;  ;  ;  ;

2024
Frontiers Media Lausanne

Frontiers in physics 12, 1257512 () [10.3389/fphy.2024.1257512]
 GO

This record in other databases:      

Please use a persistent id in citations: doi:  doi:

Abstract: ntroduction: Synchrotron radiation micro-computed tomography (SRμCT) has been used as a non-invasive technique to examine the microstructure and tissue integration of biodegradable bone implants. To be able to characterize parameters regarding the disintegration and osseointegration of such materials quantitatively, the three-dimensional (3D) image data provided by SRμCT needs to be processed by means of semantic segmentation. However, accurate image segmentation is challenging using traditional automated techniques. This study investigates the effectiveness of deep learning approaches for semantic segmentation of SRμCT volumes of Mg-based implants in sheep bone ex vivo.Methodology: For this purpose different convolutional neural networks (CNNs), including U-Net, HR-Net, U²-Net, from the TomoSeg framework, the Scaled U-Net framework, and 2D/3D U-Net from the nnU-Net framework were trained and validated. The image data used in this work was part of a previous study where biodegradable screws were surgically implanted in sheep tibiae and imaged using SRμCT after different healing periods. The comparative analysis of CNN models considers their performance in semantic segmentation and subsequent calculation of degradation and osseointegration parameters. The models’ performance is evaluated using the intersection over union (IoU) metric, and their generalization ability is tested on unseen datasets.Results and discussion: This work shows that the 2D nnU-Net achieves better generalization performance, with the degradation layer being the most challenging label to segment for all models.

Classification:

Contributing Institute(s):
  1. Helmholtz-Zentrum Hereon (Hereon)
  2. DOOR-User (DOOR ; HAS-User)
Research Program(s):
  1. 6G3 - PETRA III (DESY) (POF4-6G3) (POF4-6G3)
  2. FS-Proposal: I-20200278 (I-20200278) (I-20200278)
  3. FS-Proposal: I-20191467 (I-20191467) (I-20191467)
Experiment(s):
  1. PETRA Beamline P05 (PETRA III)
  2. PETRA Beamline P07 (PETRA III)

Appears in the scientific report 2024
Database coverage:
Medline ; Creative Commons Attribution CC BY 4.0 ; DOAJ ; OpenAccess ; Article Processing Charges ; Clarivate Analytics Master Journal List ; Current Contents - Physical, Chemical and Earth Sciences ; DOAJ Seal ; Essential Science Indicators ; Fees ; IF < 5 ; JCR ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Document types > Articles > Journal Article
Private Collections > >HEREON > Hereon
>HAS-User > HAS-User
Public records
Publications database
OpenAccess

 Record created 2024-10-24, last modified 2025-07-23


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)