Home > Publications database > Undulator linear taper control at the European X-Ray Free-Electron Laser facility |
Journal Article | PUBDB-2023-04158 |
; ; ; ;
2024
American Physical Society
College Park, MD
This record in other databases:
Please use a persistent id in citations: doi:10.1103/PhysRevAccelBeams.27.042801 doi:10.3204/PUBDB-2023-04158
Abstract: Undulator tapering controls the resonance properties of the Free-Electron Laser (FEL) amplification process. Energy losses in an undulator, caused by synchrotron radiation and wakefields within the undulator's vacuum chamber, determine the undulator's linear taper. Synchrotron radiation contribution can be calculated analytically, while calculating wakefield energy loss necessitates a beam current profile.We introduce a system for the automatic estimation of wakefield energy loss, which leverages non-invasive THz diagnostics, a current profile reconstruction algorithm enhanced with machine learning, and a recently developed analytical wakefield function for the undulator beamline. The effectiveness of this approach was validated by directly measuring wakefield-induced electron beam energy loss in the European XFEL's undulator section.
![]() |
The record appears in these collections: |