Home > Publications database > Analysis of the Test Rate for European XFEL Series Cavities |
Poster | PUBDB-2015-04970 |
; ; ; ; ;
2015
This record in other databases:
Please use a persistent id in citations: doi:10.3204/PUBDB-2015-04970
Abstract: The main part of the superconducting European XFEL linear accelerator consists of 100 accelerator modules each containing eight RF-cavities. Before the installation to a module, all of these cavities will be tested at cryogenic temperatures in a vertical cryostat in the accelerator module test facility (AMTF) at DESY. This paper discusses the average vertical test rate at the present status. It should be 1 in the ideal case, but actually it’s observed to be approximately 1.5. Classification and analysis concerning the reasons for this deviation are given as well as suggestions for a reduction of the test rate for future production cycles.
![]() |
The record appears in these collections: |
Report/Contribution to a conference proceedings
Analysis of the Test Rate for European XFEL Series Cavities
17th International Conference on RF Superconductivity, SRF2015, WhistlerWhistler, Canada, 13 Sep 2015 - 18 Sep 2015
316-318 (2015) [10.3204/PUBDB-2015-05123]