% IMPORTANT: The following is UTF-8 encoded. This means that in the presence % of non-ASCII characters, it will not work with BibTeX 0.99 or older. % Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or % “biber”. @INPROCEEDINGS{Schaffran:288423, author = {Schaffran, J. and Aderhold, Sebastian and Monaco, L. and Reschke, D. and Steder, L. and Walker, N.}, title = {{A}nalysis of the {T}est {R}ate for {E}uropean {XFEL} {S}eries {C}avities}, reportid = {PUBDB-2015-04970}, year = {2015}, note = {PrePressRelease}, abstract = {The main part of the superconducting European XFEL linear accelerator consists of 100 accelerator modules each containing eight RF-cavities. Before the installation to a module, all of these cavities will be tested at cryogenic temperatures in a vertical cryostat in the accelerator module test facility (AMTF) at DESY. This paper discusses the average vertical test rate at the present status. It should be 1 in the ideal case, but actually it’s observed to be approximately 1.5. Classification and analysis concerning the reasons for this deviation are given as well as suggestions for a reduction of the test rate for future production cycles.}, month = {Sep}, date = {2015-09-13}, organization = {17th International Conference on RF Superconductivity, Whistler (Canada), 13 Sep 2015 - 18 Sep 2015}, cin = {FLA / MPY / MHFe}, cid = {I:(DE-H253)FLA-20120731 / I:(DE-H253)MPY-20120731 / I:(DE-H253)MHFe-20210408}, pnm = {611 - Fundamental Particles and Forces (POF3-611)}, pid = {G:(DE-HGF)POF3-611}, experiment = {EXP:(DE-H253)ILC(machine)-20150101 / EXP:(DE-H253)XFEL(machine)-20150101}, typ = {PUB:(DE-HGF)24}, doi = {10.3204/PUBDB-2015-04970}, url = {https://bib-pubdb1.desy.de/record/288423}, }