%X The main part of the su­per­con­duct­ing Eu­ro­pean XFEL lin­ear ac­cel­er­a­tor con­sists of 100 ac­cel­er­a­tor mod­ules each con­tain­ing eight RF-cav­i­ties. Be­fore the in­stal­la­tion to a mod­ule, all of these cav­i­ties will be tested at cryo­genic tem­per­a­tures in a ver­ti­cal cryo­stat in the ac­cel­er­a­tor mod­ule test fa­cil­ity (AMTF) at DESY. This paper dis­cusses the av­er­age ver­ti­cal test rate at the pre­sent sta­tus. It should be 1 in the ideal case, but ac­tu­ally it’s ob­served to be ap­prox­i­mately 1.5. Clas­si­fi­ca­tion and analy­sis con­cern­ing the rea­sons for this de­vi­a­tion are given as well as sug­ges­tions for a re­duc­tion of the test rate for fu­ture pro­duc­tion cy­cles.