Abstract: We present a method to determine the sensitivity of a closed dielectric haloscope to axion dark matter. Dielectric haloscopes aim to probe the theoretically well-motivated axion mass range of ∼ 26 µeV to ∼ 500 µeV by utilizing a stack of dielectric disks and a mirror to enhance the axion-photon conversion within an external magnetic field. Their conversion volume is nearly axion-mass independent, thereby favoring large-scale designs to increase sensitivity. The large volume causes simulations to be computationally expensive and time-consuming. This paper presents a simple model that can be used to determine the sensitivity of the experiment with minimal computational resources. The model is able to describe theelectromagnetic response of a closed dielectric haloscope, accounting for realistic geometric imperfections, as well as the noise introduced by the receiver system. It is applied to data taken with a MAgnetized Disk and Mirror Axion Experiment (MADMAX) prototype within the 1.6 T Morpurgo magnet at CERN. This work underpins the first axion dark matter search using a dielectric haloscope and provides the foundation for future dark matter searches with MADMAX.
|