Home > Publications database > The laser pump X-ray probe system at LISA P08 PETRA III |
Journal Article | PUBDB-2024-04888 |
; ; ; ; ; ; ; ; ; ; ;
2024
Wiley-Blackwell
[Erscheinungsort nicht ermittelbar]
This record in other databases:
Please use a persistent id in citations: doi:10.1107/S1600577524003400 doi:10.3204/PUBDB-2024-04888
Abstract: Understanding and controlling the structure and function of liquid interfaces is a constant challenge in biology, nanoscience and nanotechnology, with applications ranging from molecular electronics to controlled drug release. X-ray reflectivity and grazing incidence diffraction provide invaluable probes for studying the atomic scale structure at liquid–air interfaces. The new time-resolved laser system at the LISA liquid diffractometer situated at beamline P08 at the PETRA III synchrotron radiation source in Hamburg provides a laser pump with X-ray probe. The femtosecond laser combined with the LISA diffractometer allows unique opportunities to investigate photo-induced structural changes at liquid interfaces on the pico- and nanosecond time scales with pump–probe techniques. A time resolution of 38 ps has been achieved and verified with Bi. First experiments include laser-induced effects on salt solutions and liquid mercury surfaces with static and varied time scales measurements showing the proof of concept for investigations at liquid surfaces.
![]() |
The record appears in these collections: |