Contribution to a conference proceedings/Journal Article PUBDB-2024-00812

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Testbeam performance results of bent ALPIDE monolithic active pixel sensors in view of the ALICE Inner Tracking System 3

 ;

2022
Inst. of Physics London

12th International Conference on Position Sensitive Detectors, PSD12, BirminghamBirmingham, United Kingdom, 12 Sep 2021 - 17 Sep 20212021-09-122021-09-17 Journal of Instrumentation 17(09), C09006 () [10.1088/1748-0221/17/09/C09006]
 GO

This record in other databases:        

Please use a persistent id in citations: doi:  doi:

Report No.: arXiv:2112.10414

Abstract: The ALICE Inner Tracking System has been recently upgraded to a full silicon detector consisting entirely of monolithic active pixel sensors, arranged in seven concentric layers around the LHC beam pipe. Further ahead, during the LHC Long Shutdown 3, the ALICE collaboration is planning to replace the three innermost layers of this new ITS with a novel vertex detector. The proposed design features wafer-scale, ultra-thin, truly cylindrical MAPS. The new sensors will be thinned down to 20–40 µm, featuring a material budget of less than 0.05% x/X $_{0}$ per layer, unprecedented low, and will be arranged concentrically around the beam pipe, as close as 18 mm from the interaction point.Anticipating the first prototypes in the new 65 nm CMOS technology node, an active R&D programme is underway to test the response to bending of existing 50 µm thick ALPIDE sensors. A number of such chips were successfully bent, even below the targeted innermost radius, without signs of mechanical damage, while retaining their full electrical functionality in laboratory tests. The curved detectors were subsequently tested during particle beam campaigns, where their particle detection performance was assessed.In this contribution, testbeam highlights from the data analysis of bent ALPIDE sensors, will be presented. It was proved that the current ALPIDE produced in the 180 nm CMOS technology retains its properties after bending. The results show an inefficiency that is generally below 10$^{−4}$, independent of the inclination and position of the impinging beam with respect to the sensor surface. This encouraging outcome proves that the use of curved MAPS is an exciting possibility for future silicon detector designs, as not only the sensor can survive the bending exercise mechanically, but the enticing attributes that make it attractive for use in the inner tracking layers are comparable to the flat state.

Keyword(s): activity report ; semiconductor detector: pixel ; semiconductor detector: technology ; semiconductor detector: design ; ALICE ; upgrade ; performance ; vertex detector ; irradiation ; mechanical engineering ; Particle tracking detectors ; Solid state detectors

Classification:

Note: 4 pages, 4 figures, proceedings for the 12th International Conference on Position Sensitive Detectors - PSD12 12-17 September, 2021, Birmingham, U.K

Contributing Institute(s):
  1. Detector RD at DESY Test beam (FHTestBeam)
Research Program(s):
  1. 6G3 - PETRA III (DESY) (POF4-6G3) (POF4-6G3)
  2. GRK 2058 - GRK 2058: High Resolution and High Rate Detectors in Nuclear and Particle Physics (HighRR) (252537693) (252537693)
Experiment(s):
  1. DESY: TestBeamline 24 (DESY II)

Database coverage:
Medline ; Creative Commons Attribution CC BY 4.0 ; OpenAccess ; Clarivate Analytics Master Journal List ; Current Contents - Physical, Chemical and Earth Sciences ; Essential Science Indicators ; National-Konsortium ; SCOPUS ; Science Citation Index Expanded ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >FH > FHTestBeam
Document types > Events > Contributions to a conference proceedings
Document types > Articles > Journal Article
Public records
Publications database
OpenAccess


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Preprint  ;
Testbeam performance results of bent ALPIDE monolithic active pixel sensors in view of the ALICE Inner Tracking System 3
[10.3204/PUBDB-2024-07755]  GO OpenAccess  Download fulltext Files  Download fulltextFulltext by arXiv.org BibTeX | EndNote: XML, Text | RIS


 Record created 2024-02-16, last modified 2025-07-24