Home > Publications database > Dose rates calculations from electron beam losses on XS1 dump at XFEL |
Internal Report | PUBDB-2022-01873 |
; ; ;
2021
This record in other databases:
Please use a persistent id in citations: doi:10.3204/PUBDB-2022-01873
Report No.: DESY-D3–130
Abstract: The report documents dose rate calculations with FLUKA as a result of 14 GeV electron beamlosses within the UG4 level dump pit at XS1. Locations of interest include the UG4 dumppit itself (dump window activation) to the UG3 level above it (sensitive electronics) and to theUG2 level (neutron field characterization). Comparisons between FLUKA and measurementsare made where available and show good agreement between simulated dose rates and measureddose rates.
![]() |
The record appears in these collections: |