Internal Report PUBDB-2022-01873

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Dose rates calculations from electron beam losses on XS1 dump at XFEL

 ;  ;  ;

2021

20 pp. () [10.3204/PUBDB-2022-01873]  GO

This record in other databases:

Please use a persistent id in citations: doi:

Report No.: DESY-D3–130

Abstract: The report documents dose rate calculations with FLUKA as a result of 14 GeV electron beamlosses within the UG4 level dump pit at XS1. Locations of interest include the UG4 dumppit itself (dump window activation) to the UG3 level above it (sensitive electronics) and to theUG2 level (neutron field characterization). Comparisons between FLUKA and measurementsare made where available and show good agreement between simulated dose rates and measureddose rates.


Contributing Institute(s):
  1. Strahlenschutz (D3)
Research Program(s):
  1. 899 - ohne Topic (POF4-899) (POF4-899)
Experiment(s):
  1. No specific instrument

Database coverage:
OpenAccess
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >DIR > >DIB > >D > D3
Document types > Reports > Internal Reports
Public records
Publications database
OpenAccess

 Record created 2022-04-21, last modified 2022-04-21


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)