| Home > Publications database > Simulating nanomechanical cryogenic gas pressure sensors with fiber-optical readout |
| Contribution to a conference proceedings/Journal Article | PUBDB-2026-03114 |
; ; ; ; ; ; ;
2026
SPIE
Bellingham, Wash.
This record in other databases:
Please use a persistent id in citations: doi:10.1117/12.3106240
Abstract: The gas-induced damping of nanomechanical membrane resonators was recently demonstrated as a calibration-free measure for absolute gas pressure with a wide measurement range from atmospheric pressure to high vacuum. However, the practical application of these sensors has been limited so far due to the use of a sensitive tabletop free-space optical interferometer readout setup. An all-optical-fiber readout could address this issue, improve the flexibility in sensor positioning and enable broad applicability. Here, we present modeling of a direct interface between an optical fiber and a silicon nitride membrane, forming a compact Fabry-Pérot interferometer. An analytical plane wave spectrum method as well as numerical finite-difference time-domain simulations were used to model the interferometric sensitivity depending on the geometric alignment between the fiber tip and the membrane surface. We find that realistically attainable angular misalignments less than 1° and fiber-membrane-separations less than 20µm yield sensitivities matching a free-space interferometer, which is sufficient to resolve the membrane’s thermally driven motion at atmospheric pressure with a high signal-to-noise ratio ∼ 100. Motivated by the need in fundamental physics experiments – such as future gravitational wave observatories – for a cryo-compatible gas pressure sensor suitable for high-vacuum (< 10−³mbar) measurements, and by the lack of a corresponding commercial solution, we measure the pressure in a cryogenic vacuum enclosure at 78K using our novel nanomechanical gas pressure sensor. This is enabled by its compact fiber-optical readout, which alleviates the need for direct optical access to the cold volume. To validate these pressure readings, we compare them to measurements of commercial pressure sensors operating at room temperature connected to the enclosure via a long, thin pipe. To account for pressure gradients arising in this setup due to temperature gradients and gas flows, we model the gas pressure distribution using a rarefied gas simulation. Our models agree within 13% with measurements obtained using our sensor, in line with the measurement uncertainties of the commercial pressure sensors and model uncertainties.
|
The record appears in these collections: |