Preprint PUBDB-2026-00229

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2026

This record in other databases:    

Please use a persistent id in citations: doi:

Report No.: arXiv:2501.13562

Abstract: MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of 200e−. Threshold calibration is crucial to understanding the charge collection in the pixel. A simple procedure is developed to calibrate the threshold to unit electrons making use of a dedicated charge injection circuit and an Fe-55 source with dominant charge deposition of 1611e−. The injection voltage corresponding to the signal under exposure of Fe-55 is determined and serves as the basis for charge calibration. The charge injection circuit incorporates a capacitance with design value of Cinj=230aF. Experimentally, the average capacitance value for non-irradiated samples is found to be Cinj,exp=255±35aF and varies between sensors by 14% in terms of standard deviation. The deviation from the design value as well as among sensors motivates the need for the presented calibration procedure, which is proposed to be performed for each MALTA2 sensor and reduces the uncertainty down to 3% depending on the sensor.

Keyword(s): DMAPS ; Charge calibration ; Tracking ; High-energy physics

Classification:

Contributing Institute(s):
  1. Z_DET (Z_DET)
Research Program(s):
  1. 622 - Detector Technologies and Systems (POF4-622) (POF4-622)
  2. AIDAinnova - Advancement and Innovation for Detectors at Accelerators (101004761) (101004761)
  3. AIDA-2020 - Advanced European Infrastructures for Detectors at Accelerators (654168) (654168)
  4. STREAM - Smart Sensor Technologies and Training for Radiation Enhanced Applications andMeasurements (675587) (675587)
Experiment(s):
  1. Measurement at external facility

Database coverage:
Creative Commons Attribution CC BY 4.0 ; OpenAccess ; Published
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >ZEUTHEN > Z_DET
Document types > Reports > Preprints
Public records
Publications database
OpenAccess


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;
Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
Nuclear instruments & methods in physics research / Section A 1082, 170972 () [10.1016/j.nima.2025.170972]  GO OpenAccess  Download fulltext Files  Download fulltextFulltext by arXiv.org BibTeX | EndNote: XML, Text | RIS


 Record created 2026-01-13, last modified 2026-01-18


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
External link:
Download fulltextFulltext by arXiv.org
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)