Home > Publications database > Study of hybrid micropattern gaseous detector with CsI photocathode for Super Tau-Charm facility RICH |
Journal Article | PUBDB-2024-00364 |
; ; ; ; ; ; ; ; ; ; ;
2023
Inst. of Physics
London
This record in other databases:
Please use a persistent id in citations: doi:10.1088/1748-0221/18/04/P04028
Report No.: arXiv:2205.01822
Abstract: Super τ-Charm facility (STCF) is a future electron-positron collider operating in theτ-Charm energy region with the aim of studying hadron structure and spectroscopy. Thebaseline design of the STCF barrel particle identification (PID) detector, which covers momentumup to 2 GeV/c, is provided by a Ring Imaging Cherenkov Counter (RICH). The RICH features anapproximately focusing design with liquid perfluorohexane sealed in a quartz container as theradiator and a hybrid combination of CsI-coated THGEMs and Micromegas as the photo-electrondetector. A 16×16 cm$^{2}$ prototype with a quartz radiator has been built and tested atDESY and stably operated with an effective gain of 10$^{5}$. In this paper, the design,performance, and reconstruction algorithm of RICH detectors are discussed.
Keyword(s): cesium: iodine ; RICH ; particle identification ; quarz ; photomultiplier ; angular resolution ; Micromegas ; gas electron multiplier ; performance ; electron positron: colliding beams ; detector: design ; micro-pattern detector ; data analysis method ; Cherenkov detectors ; Micropattern gaseous detectors (MSGC ; GEM ; THGEM ; RETHGEM ; MHSP ; MICROPIC ; MICROMEGAS ; InGrid ; etc) ; Particle identification methods ; MicroMegas ; MPGD ; STCF ; RICH ; PID
![]() |