Report/Journal Article PUBDB-2017-10155

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
First functionality tests of a 64 × 64 pixel DSSC sensor module connected to the complete ladder readout

 ;  ;  ;  ;  ;  ;  ;

2017
Inst. of Physics London

18th International Workshop on Radiation Imaging Detectors (IWORID 2016), BarcelonaBarcelona, Spain, 3 Jul 2016 - 7 Jul 20162016-07-032016-07-07 Journal of Instrumentation 12(03), C03025 - C03025 () [10.1088/1748-0221/12/03/C03025]
 GO

This record in other databases:        

Please use a persistent id in citations: doi:

Report No.: arXiv:1701.03613

Abstract: The European X-ray Free Electron Laser (XFEL.EU) will provide every 0.1 s a train of 2700 spatially coherent ultrashort X-ray pulses at 4.5 MHz repetition rate. The Small Quantum Systems (SQS) instrument and the Spectroscopy and Coherent Scattering instrument (SCS) operate with soft X-rays between 0.5 keV–6 keV. The DEPFET Sensor with Signal Compression (DSSC) detector is being developed to meet the requirements set by these two XFEL.EU instruments. The DSSC imager is a 1 mega-pixel camera able to store up to 800 single-pulse images per train. The so-called ladder is the basic unit of the DSSC detector. It is the single unit out of sixteen identical-units composing the DSSC-megapixel camera, containing all representative electronic components of the full-size system and allows testing the full electronic chain. Each DSSC ladder has a focal plane sensor with 128× 512 pixels. The read-out ASIC provides full-parallel readout of the sensor pixels. Every read-out channel contains an amplifier and an analog filter, an up-to 9 bit ADC and the digital memory. The ASIC amplifier have a double front-end to allow one to use either DEPFET sensors or Mini-SDD sensors. In the first case, the signal compression is a characteristic intrinsic of the sensor, in the second case, the compression is implemented at the first amplification stage. The goal of signal compression is to meet the requirement of single-photon detection capability and wide dynamic range. We present the first results of measurements obtained using a 64× 64 pixel DEPFET sensor attached to the full final electronic and data-acquisition chain.

Classification:

Note: Preprint: PUBDB-2017-00572

Contributing Institute(s):
  1. European XFEL Projekt Team (Eur.XFEL)
  2. Mikro- und Optoelektronik (FEC)
Research Program(s):
  1. 6G13 - XFEL (POF3-622) (POF3-622)
Experiment(s):
  1. No specific instrument

Appears in the scientific report 2017
Database coverage:
Medline ; Current Contents - Physical, Chemical and Earth Sciences ; IF < 5 ; JCR ; NationallizenzNationallizenz ; SCOPUS ; Science Citation Index Expanded ; Thomson Reuters Master Journal List ; Web of Science Core Collection
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >FH > >FE > FEC
Private Collections > >XFEL.EU > Eur.XFEL
Document types > Articles > Journal Article
Document types > Reports > Reports
Public records
Publications database


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Preprint/Report  ;  ;  ;  ;  ;  ;  ;
First functionality tests of a 64 x 64 pixel DSSC sensor module connected to the complete ladder readout
[10.3204/PUBDB-2017-00572]  GO OpenAccess  Download fulltext Files  Download fulltextFulltext Download fulltextFulltext by arXiv.org BibTeX | EndNote: XML, Text | RIS


 Record created 2017-08-31, last modified 2025-07-20


Restricted:
Download fulltext PDF Download fulltext PDF (PDFA)
External link:
Download fulltextFulltext by arXiv.org
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)