Preprint/Internal Report PUBDB-2015-05223

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
A Calibration System for Compton Polarimetry at $e^+e^-$ Linear Colliders

 ;  ;

2015

 GO

This record in other databases:  

Report No.: DESY-15-170; arXiv:1509.03178

Abstract: Polarimetry with permille-level precision is essential for future electron-positron linear colliders. Compton polarimeters can reach negligible statistical uncertainties within seconds of measurement time. The dominating systematic uncertainties originate from the response and alignment of the detector which records the Compton scattered electrons. The robust baseline technology for the Compton polarimeters foreseen at future linear colliders is based on an array of gas Cherenkov detectors read out by photomultipliers. In this paper, we will present a calibration method which promises to monitor nonlinearities in the response of such a detector at the level of a few permille. This method has been implemented in an LED-based calibration system which matches the existing prototype detector. The performance of this calibration system is sufficient to control the corresponding contribution to the total uncertainty on the extracted polarisation to better than $0.1\%$.


Contributing Institute(s):
  1. Experimente an Lepton Collidern (FLC)
Research Program(s):
  1. 632 - Detector technology and systems (POF3-632) (POF3-632)
  2. 611 - Fundamental Particles and Forces (POF3-611) (POF3-611)
Experiment(s):
  1. Facility (machine) ILC

Appears in the scientific report 2015
Database coverage:
OpenAccess ; Published
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >FH > FLC
Document types > Reports > Internal Reports
Document types > Reports > Preprints
Public records
Publications database
OpenAccess


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;
A calibration system for Compton polarimetry at $e^+ e^−$ linear colliders
Journal of Instrumentation 11(01), P01014 () [10.1088/1748-0221/11/01/P01014]  GO OpenAccess  Download fulltext Files  Download fulltextFulltext Download fulltextFulltext by arXiv.org BibTeX | EndNote: XML, Text | RIS


 Record created 2015-12-01, last modified 2021-11-10


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
External link:
Download fulltextFulltext by arXiv.org
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)