MALTA-Cz: A radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

2023

This record in other databases:  

Please use a persistent id in citations: doi:

Report No.: arXiv:2301.03912

Abstract: Depleted Monolithic Active Pixel Sensor (DMAPS) sensors developed in the Tower Semiconductor 180 nm CMOS imaging process have been designed in the context of the ATLAS ITk upgrade Phase-II at the HL-LHC and for future collider experiments. The ``MALTA-Czochralski (MALTA-Cz)'' full size DMAPS sensor has been developed with the goal to demonstrate a radiation hard, thin CMOS sensor with high granularity, high hit-rate capability, fast response time and superior radiation tolerance. The small pixel size ($36.4\times 36.4$~$\mu$m$^2$) provides high spatial resolution. Its asynchronous readout architecture is designed for high hit-rates and fast time response in triggered and trigger-less detector applications. The readout architecture is designed to stream all hit data to the multi-channel output which allows an off-sensor trigger formation and the use of hit-time information for event tagging. The sensor manufacturing has been optimised through process adaptation and special implant designs to allow the manufacturing of small electrode DMAPS on thick high-resistivity p-type Czochralski substrate. The special processing ensures excellent charge collection and charge particle detection efficiency even after a high level of radiation. Furthermore the special implant design and use of a Czochralski substrate improves the sensor's time resolution. This paper presents a summary of sensor design optimisation through process and implant choices and TCAD simulation to model the signal response. Beam and laboratory test results on unirradiated and irradiated sensors have shown excellent detection efficiency after a dose of $2\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$. The time resolution of the sensor is measured to be $\sigma=2$~ns.

Keyword(s): detector: design ; semiconductor detector: pixel ; fabrication ; pixel: size ; charge: yield ; time resolution ; efficiency ; electrode ; spatial resolution ; ATLAS ; radiation: damage ; tracking detector: upgrade


Contributing Institute(s):
  1. Z_DET (Z_DET)
Research Program(s):
  1. 622 - Detector Technologies and Systems (POF4-622) (POF4-622)
Experiment(s):
  1. No specific instrument

Appears in the scientific report 2023
Database coverage:
Creative Commons Attribution CC BY 4.0 ; OpenAccess ; Published
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > >ZEUTHEN > Z_DET
Document types > Reports > Preprints
Public records
Publications database
OpenAccess


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;
MALTA-Cz: a radiation hard full-size monolithic CMOS sensor with small electrodes on high-resistivity Czochralski substrate
Journal of Instrumentation 18(09), P09018 () [10.1088/1748-0221/18/09/P09018]  GO OpenAccess  Download fulltext Files  Download fulltextFulltext by arXiv.org BibTeX | EndNote: XML, Text | RIS


 Record created 2023-02-06, last modified 2023-10-22


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
External link:
Download fulltextFulltext by arXiv.org
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)