http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png
Results from pion calibration runs for the H 1 liquid argon calorimeter and comparisons with simulations

 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;

1993

23 pp. () [10.3204/PUBDB-2023-00155]  GO

This record in other databases:    

Please use a persistent id in citations: doi:

Report No.: DESY-93-047

Abstract: We present results on calibration runs performed with pions at the CERN SPS for different modules of the H 1 liquid argon calorimeter which consists of an electromagnetic section with lead absorbers and a hadronic section with steel absorbers. The data cover an energy range from 3.7 to 205 GeV. Detailed comparisons of the data and simulation with GHEISHA 8 in the framework of GEANT 3.14 are presented. The measured pion induced shower profiles are well described by the simulation. The total signal of pions on an energy scale determined from electron measurements is reproduced to better than 3% in various module configurations. After application of weighting functions, determined from Monte Carlo data and needed to achieve compensation, the reconstructed measured energies agree with simulation to about 3%. The energies of hadronic showers are reconstructed with a resolution of about ⨸50%√E⨸ 2%. This result is achieved by inclusion of signals from an iron streamer tube tail catcher behind the liquid argon stacks.

Keyword(s): calorimeter: liquid argon ; calorimeter: energy resolution ; calibration ; particle identification: (pi electron) ; showers ; numerical calculations: Monte Carlo ; H1 ; DESY DESY HERA Stor Stor

Classification:

Note: H1

Contributing Institute(s):
  1. DESY Retrocat (DESY(-2012))
Research Program(s):
  1. 899 - ohne Topic (POF3-899) (POF3-899)
Experiment(s):
  1. No specific instrument

Database coverage:
OpenAccess
Click to display QR Code for this record

The record appears in these collections:
Private Collections > >DESY > DESY(-2012)
Document types > Reports > Reports
Public records
Publications database
OpenAccess


Linked articles:

http://join2-wiki.gsi.de/foswiki/pub/Main/Artwork/join2_logo100x88.png Journal Article  ;  ;  ; et al
Results from pion calibration runs for the H 1 liquid argon calorimeter and comparisons with simulations
Nuclear instruments & methods in physics research / A 336(3), 499 - 509 () [10.1016/0168-9002(93)91258-O]  GO  Download fulltext Files BibTeX | EndNote: XML, Text | RIS


 Record created 2023-01-13, last modified 2023-01-13


OpenAccess:
Download fulltext PDF Download fulltext PDF (PDFA)
Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)