TY - JOUR
AU - Echelmeier, Austin
AU - Cruz Villarreal, Jorvani
AU - Messerschmidt, Marc
AU - Kim, Daihyun
AU - Coe, Jesse
AU - Thifault, Darren
AU - Botha, Sabine
AU - Egatz-Gomez, Ana
AU - Gandhi, Sahir
AU - Brehm, Gerrit
AU - Conrad, Chelsie E.
AU - Hansen, Debra T.
AU - Madsen, Caleb
AU - Bajt, Saša
AU - Meza-Aguilar, J. Domingo
AU - Oberthür, Dominik
AU - Wiedorn, Max O.
AU - Fleckenstein, Holger
AU - Mendez, Derek
AU - Knoska, Juraj
AU - Martin-Garcia, Jose M.
AU - Hu, Hao
AU - Lisova, Stella
AU - Allahgholi, Aschkan
AU - Gevorkov, Yaroslav
AU - Ayyer, Kartik
AU - Aplin, Steve
AU - Ginn, Helen
AU - Graafsma, Heinz
AU - Morgan, Andrew J.
AU - Greiffenberg, Dominic
AU - Klujev, Alexander
AU - Laurus, Torsten
AU - Poehlsen, Jennifer
AU - Trunk, Ulrich
AU - Mezza, Davide
AU - Schmidt, Bernd
AU - Kuhn, Manuela
AU - Fromme, Raimund
AU - Sztuk-Dambietz, Jolanta
AU - Raab, Natascha
AU - Hauf, Steffen
AU - Silenzi, Alessandro
AU - Michelat, Thomas
AU - Xu, Chen
AU - Danilevski, Cyril
AU - Parenti, Andrea
AU - Mekinda, Leonce
AU - Weinhausen, Britta
AU - Mills, Grant
AU - Vagovic, Patrik
AU - Kim, Yoonhee
AU - Kirkwood, Henry
AU - Bean, Richard
AU - Bielecki, Johan
AU - Stern, Stephan
AU - Giewekemeyer, Klaus
AU - Round, Adam R.
AU - Schulz, Joachim
AU - Dörner, Katerina
AU - Grant, Thomas
AU - Mariani, Valerio
AU - Barty, Anton
AU - Mancuso, Adrian P.
AU - Weierstall, Uwe
AU - Spence, John C. H.
AU - Chapman, Henry N.
AU - Zatsepin, Nadia
AU - Fromme, Petra
AU - Kirian, Richard
AU - Ros, Alexandra
TI - Segmented flow generator for serial crystallography at the European X-ray free electron laser
JO - Nature Communications
VL - 11
IS - 1
SN - 2041-1723
CY - [London]
PB - Nature Publishing Group UK
M1 - PUBDB-2020-03402
SP - 4511
PY - 2020
AB - Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99
LB - PUB:(DE-HGF)16
C6 - pmid:32908128
UR - <Go to ISI:>//WOS:000600547200012
DO - DOI:10.1038/s41467-020-18156-7
UR - https://bib-pubdb1.desy.de/record/448374
ER -