% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INPROCEEDINGS{Lamblin:408362,
      author       = {Lamblin, J. and Bosson, G. and Bourrion, O. and Guillaudin,
                      O. and Mayet, F. and Muraz, J.-F. and Richer, J.-P. and
                      Riffard, Q. and Santos, D. and Busto, J. and Brunner, J. and
                      Fouchez, D. and Lebreton, L. and Maire, D.},
      title        = {{D}ark matter directional detection with {MIMAC}},
      address      = {Hamburg},
      publisher    = {Verlag Deutsches Elektronen-Synchrotron},
      reportid     = {PUBDB-2018-02815, DESY-PROC-2013-04},
      isbn         = {978-3-935702-83-6},
      series       = {DESY-PROC},
      pages        = {211-214},
      year         = {2013},
      comment      = {Lamblin, J. "Dark matter directional detection with MIMAC"
                      in Proceedings, 9th Patras Workshop on Axions, WIMPs and
                      WISPs (AXION-WIMP 2013) / Oberlack, Uwe, Sissol, Pierre
                      (eds.), 2013 ; AXION-WIMP 2013 : 9th Patras Workshop on
                      Axions, WIMPs and WISPs , 2013-06-23 - 2013-06-28, Mainz},
      booktitle     = {Lamblin, J. "Dark matter directional
                       detection with MIMAC" in Proceedings,
                       9th Patras Workshop on Axions, WIMPs
                       and WISPs (AXION-WIMP 2013) / Oberlack,
                       Uwe, Sissol, Pierre (eds.), 2013 ;
                       AXION-WIMP 2013 : 9th Patras Workshop
                       on Axions, WIMPs and WISPs , 2013-06-23
                       - 2013-06-28, Mainz},
      abstract     = {The MIMAC project aims at the directional detection of dark
                      matter using a gaseous Time Projection Chamber (TPC) which
                      enables the measurement of the energy and the track of low
                      energy nuclear recoils. A 5-liter prototype has been
                      developed and operated during several months. In this paper,
                      after a description of the detector and the calibration
                      procedure, we report the first results of the background
                      studies.},
      month         = {Jun},
      date          = {2013-06-24},
      organization  = {9th Patras Workshop on Axions, WIMPs
                       and WISPs, Mainz (Germany), 24 Jun 2013
                       - 28 Jun 2013},
      keywords     = {Hypothetisches Teilchen (gnd)},
      cin          = {L},
      cid          = {I:(DE-H253)L-20120731},
      pnm          = {899 - ohne Topic (POF3-899)},
      pid          = {G:(DE-HGF)POF3-899},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)29 / PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      doi          = {10.3204/DESY-PROC-2013-04/lamblin_jacob},
      url          = {https://bib-pubdb1.desy.de/record/408362},
}