% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@INPROCEEDINGS{Paetzold:398358,
author = {Paetzold, Torsten and Petersen, Bernd and Schnautz, Tobias
and Ueresin, Can and Zajac, Juliusz},
title = {{F}irst {O}peration of the {XFEL} {L}inac with the 2 {K}
{C}ryogenic {S}ystem},
reportid = {PUBDB-2017-13933},
pages = {8},
year = {2017},
abstract = {The RF operation of the about 800 superconducting 1.3 GHz
9-cell cavities of the XFEL linac requires helium II bath
cooling at 2 K, corresponding to a vapor pressure of 3100
Pa. After the first cool-down of the XFEL linac to 4 K in
December, 27th 2016 the operation of the 2 K cryogenic
system was started in January, 2nd 2017. The 2 K cryogenic
system consist of a 4-stage set of cold compressors to
compress helium vapor at a mass flow of up to 100 g/s from
2400 Pa to about 110 kPa and a full flow bypass with an
arrangement of heat exchangers and control valves. This
paper describes the XFEL refrigerating plant, especially the
2 K cryogenic system, thetuning of the cold compressor
regulation to adapt to the XFEL linac static and dynamicheat
loads and experience of about 6 months of operation.},
month = {Jul},
date = {2017-07-09},
organization = {2017 Cryogenic Engineering Conference
and International Cryogenic Materials
Conference, Madison (USA), 9 Jul 2017 -
13 Jul 2017},
cin = {MKS},
cid = {I:(DE-H253)MKS-20120806},
pnm = {6G13 - XFEL (POF3-622)},
pid = {G:(DE-HGF)POF3-6G13},
experiment = {EXP:(DE-H253)XFEL(machine)-20150101},
typ = {PUB:(DE-HGF)8},
doi = {10.3204/PUBDB-2017-13933},
url = {https://bib-pubdb1.desy.de/record/398358},
}