001     288118
005     20250717105358.0
024 7 _ |a 10.1364/OE.23.028459
|2 doi
024 7 _ |a WOS:000366578900037
|2 WOS
024 7 _ |a 10.3204/PUBDB-2015-04830
|2 datacite_doi
024 7 _ |a pmid:26561117
|2 pmid
024 7 _ |a openalex:W2194718613
|2 openalex
037 _ _ |a PUBDB-2015-04830
041 _ _ |a English
082 _ _ |a 530
100 1 _ |a Yefanov, Oleksandr
|0 P:(DE-H253)PIP1006155
|b 0
|e Corresponding author
|u desy
245 _ _ |a Accurate determination of segmented X-ray detector geometry
260 _ _ |a Washington, DC
|c 2015
|b Soc.
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1463053078_23336
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Recent advances in X-ray detector technology have resulted in the introduction of segmented detectors composed of many small detector modules tiled together to cover a large detection area. Due to mechanical tolerances and the desire to be able to change the module layout to suit the needs of different experiments, the pixels on each module might not align perfectly on a regular grid. Several detectors are designed to permit detector sub-regions (or modules) to be moved relative to each other for different experiments. Accurate determination of the location of detector elements relative to the beam-sample interaction point is critical for many types of experiment, including X-ray crystallography, coherent diffractive imaging (CDI), small angle X-ray scattering (SAXS) and spectroscopy. For detectors with moveable modules, the relative positions of pixels are no longer fixed, necessitating the development of a simple procedure to calibrate detector geometry after reconfiguration. We describe a simple and robust method for determining the geometry of segmented X-ray detectors using measurements obtained by serial crystallography. By comparing the location of observed Bragg peaks to the spot locations predicted from the crystal indexing procedure, the position, rotation and distance of each module relative to the interaction region can be refined. We show that the refined detector geometry greatly improves the results of experiments.
536 _ _ |a 6215 - Soft Matter, Health and Life Sciences (POF3-621)
|0 G:(DE-HGF)POF3-6215
|c POF3-621
|f POF III
|x 0
536 _ _ |a AXSIS - Frontiers in Attosecond X-ray Science: Imaging and Spectroscopy (609920)
|0 G:(EU-Grant)609920
|c 609920
|f ERC-2013-SyG
|x 1
536 _ _ |a NANOMEM - Membrane Protein Nanocrystallography (317079)
|0 G:(EU-Grant)317079
|c 317079
|f FP7-PEOPLE-2012-ITN
|x 2
536 _ _ |a 05E13GU1 - Entwicklung eines "Serial Femtosecond Crystallography (SFX)"-Messtandes am Europäischen Elektronenlaser XFEL (BMBF-05E13GU1)
|0 G:(DE-H253)BMBF-05E13GU1
|c BMBF-05E13GU1
|x 3
588 _ _ |a Dataset connected to CrossRef
693 _ _ |0 EXP:(DE-H253)CFEL-Exp-20150101
|5 EXP:(DE-H253)CFEL-Exp-20150101
|e Experiments at CFEL
|x 0
693 _ _ |0 EXP:(DE-MLZ)External-20140101
|5 EXP:(DE-MLZ)External-20140101
|e Measurement at external facility
|x 1
700 1 _ |a Mariani, Valerio
|0 P:(DE-H253)PIP1021498
|b 1
|u desy
700 1 _ |a Gati, Cornelius
|0 P:(DE-H253)PIP1017962
|b 2
700 1 _ |a White, Thomas A.
|0 P:(DE-HGF)0
|b 3
700 1 _ |a Chapman, Henry N.
|0 P:(DE-H253)PIP1006324
|b 4
|u desy
700 1 _ |a Barty, Anton
|0 P:(DE-H253)PIP1008245
|b 5
|u desy
773 _ _ |a 10.1364/OE.23.028459
|g Vol. 23, no. 22, p. 28459 -
|0 PERI:(DE-600)1491859-6
|n 22
|p 28459 - 28470
|t Optics express
|v 23
|y 2015
|x 1094-4087
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.pdf
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.gif?subformat=icon
|x icon
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.jpg?subformat=icon-1440
|x icon-1440
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.jpg?subformat=icon-180
|x icon-180
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.jpg?subformat=icon-640
|x icon-640
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/288118/files/10.1364_OE.23.028459Yefanov.pdf?subformat=pdfa
|x pdfa
|y OpenAccess
909 C O |o oai:bib-pubdb1.desy.de:288118
|p openaire
|p open_access
|p driver
|p VDB
|p ec_fundedresources
|p dnbdelivery
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 0
|6 P:(DE-H253)PIP1006155
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 0
|6 P:(DE-H253)PIP1006155
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 1
|6 P:(DE-H253)PIP1021498
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 1
|6 P:(DE-H253)PIP1021498
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 2
|6 P:(DE-H253)PIP1017962
910 1 _ |a Europäisches Laboratorium für Molekularbiologie
|0 I:(DE-588b)235011-7
|k EMBL
|b 2
|6 P:(DE-H253)PIP1017962
910 1 _ |a Externes Institut
|0 I:(DE-HGF)0
|k >Extern
|b 2
|6 P:(DE-H253)PIP1017962
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 4
|6 P:(DE-H253)PIP1006324
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 4
|6 P:(DE-H253)PIP1006324
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 5
|6 P:(DE-H253)PIP1008245
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 5
|6 P:(DE-H253)PIP1008245
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF3-620
|0 G:(DE-HGF)POF3-621
|2 G:(DE-HGF)POF3-600
|v In-house research on the structure, dynamics and function of matter
|9 G:(DE-HGF)POF3-6215
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2015
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0300
|2 StatID
|b Medline
915 _ _ |a JCR
|0 StatID:(DE-HGF)0100
|2 StatID
|b OPT EXPRESS : 2014
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0150
|2 StatID
|b Web of Science Core Collection
915 _ _ |a WoS
|0 StatID:(DE-HGF)0110
|2 StatID
|b Science Citation Index
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0500
|2 StatID
|b DOAJ
915 _ _ |a IF < 5
|0 StatID:(DE-HGF)9900
|2 StatID
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)1150
|2 StatID
|b Current Contents - Physical, Chemical and Earth Sciences
915 _ _ |a WoS
|0 StatID:(DE-HGF)0111
|2 StatID
|b Science Citation Index Expanded
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0199
|2 StatID
|b Thomson Reuters Master Journal List
920 1 _ |0 I:(DE-H253)FS-CFEL-1-20120731
|k FS-CFEL-1
|l CFEL-Coherent X-Ray Imaging
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a I:(DE-H253)FS-CFEL-1-20120731
980 1 _ |a UNRESTRICTED
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21