@INPROCEEDINGS{Stacey:637975,
author = {Stacey, Blae and Kuropka, Willi and Vinatier, Thomas and
Hillert, Wolfgang},
title = {{S}mith-{P}urcell and {T}ransition {R}adiation {B}ased
{C}harged {P}article {B}eam {D}iagnostics for the
{F}emtosecond-{R}ange},
address = {Geneva},
publisher = {JACoW Publishing},
reportid = {PUBDB-2025-03944},
isbn = {978-3-95450-262-2},
pages = {715 - 717},
year = {2025},
comment = {[Ebook] The Fourteenth International Beam Instrumentation
Conference : Liverpool, UK, 7-11 September 2025 : full
proceedings / Welsch, Carsten P. , [Geneva, Switzerland] :
JACoW Publishing, [2026],},
booktitle = {[Ebook] The Fourteenth International
Beam Instrumentation Conference :
Liverpool, UK, 7-11 September 2025 :
full proceedings / Welsch, Carsten P. ,
[Geneva, Switzerland] : JACoW
Publishing, [2026],},
abstract = {We will give an overview of the Smith-Purcell and
transition radiation based longitudinal diagnostic methods
employed at the ARES (Accelerator Research Experiment at
SINBAD) linear accelerator to characterize femto-second long
electron bunches. The Smith-Purcell radiation mechanism has
been studied for the case of metallic gratings, but not much
experimental data has been published yet with respect to
dielectric gratings as charged particle beam diagnostic
devices. We expect a number of advantages in the detection
of the radiation at the substrate side and the spectral
properties of the radiation tailored by the geometric shape
of the grating structures. Due to the advances in
lithographic techniques dielectric gratings can be produced
with optical wavelength periodicities and the shapes can be
controlled with nano-meter precision. For femto-second bunch
lengths the coherence of transition radiation starts to
reach the near-infrared to optical regime. This opens up the
possibility of characterizing the spectrum with readily
available high sensitivity semi-conductor based detectors to
draw conclusions on the form factor and measure bunch
lengths.},
month = {Sep},
date = {2025-09-07},
organization = {The 14th International Beam
Instrumentation Conference, Liverpool
(UK), 7 Sep 2025 - 11 Sep 2025},
keywords = {Accelerator Physics (Other) / MC05 - MC05: Longitudinal
Diagnostics and Synchronization (Other)},
cin = {MIL},
cid = {I:(DE-H253)MIL-20240919},
pnm = {621 - Accelerator Research and Development (POF4-621)},
pid = {G:(DE-HGF)POF4-621},
experiment = {EXP:(DE-H253)ARES-20200101},
typ = {PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
doi = {10.18429/JACoW-IBIC2025-WEPMO03},
url = {https://bib-pubdb1.desy.de/record/637975},
}