000632184 001__ 632184
000632184 005__ 20250723110057.0
000632184 0247_ $$2doi$$a10.1016/j.compositesb.2025.112692
000632184 0247_ $$2ISSN$$a1359-8368
000632184 0247_ $$2ISSN$$a1879-1069
000632184 0247_ $$2openalex$$aopenalex:W4411369618
000632184 037__ $$aPUBDB-2025-02112
000632184 041__ $$aEnglish
000632184 082__ $$a660
000632184 1001_ $$0P:(DE-H253)PIP1107269$$aPoellinger, Alexander$$b0$$eCorresponding author
000632184 245__ $$aThe effect of PTFE on the deformation behavior of PPS composites for high-pressure hydrogen applications
000632184 260__ $$aAmsterdam [u.a.]$$bElsevier$$c2025
000632184 3367_ $$2DRIVER$$aarticle
000632184 3367_ $$2DataCite$$aOutput Types/Journal article
000632184 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1752239633_3463688
000632184 3367_ $$2BibTeX$$aARTICLE
000632184 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000632184 3367_ $$00$$2EndNote$$aJournal Article
000632184 500__ $$aWaiting for fulltext
000632184 520__ $$aEfficient storage of hydrogen is crucial for the widespread adoption of renewable energy. Reciprocatingpiston compressors, featuring advanced sealing solutions, are essential to meet the stringent demands ofnon-lubricated hydrogen applications, ensuring gas purity and high pressure differentials. Polyphenylenesulfide polymer matrix composites exhibit high mechanical strength and low friction and wear, making themvaluable in tribological applications. This study investigates carbon fiber reinforced polyphenylene sulfidemodifications with different PTFE contents by employing advanced imaging techniques to assess the effect ofdry-lubricant on properties with respect to application in high-pressure reciprocating compressors. Thermo-mechanical and tribological testing, along with microstructure analysis utilizing synchrotron tomography,presents the importance of dry lubricating PTFE additives. Furthermore, the research provides insightsinto the micromechanical deformation behavior of short fiber reinforced polymers and identifies promisingcompositions suitable for advanced hydrogen compression.
000632184 536__ $$0G:(DE-HGF)POF4-6G3$$a6G3 - PETRA III (DESY) (POF4-6G3)$$cPOF4-6G3$$fPOF IV$$x0
000632184 536__ $$0G:(DE-H253)I-20230472-EC$$aFS-Proposal: I-20230472 EC (I-20230472-EC)$$cI-20230472-EC$$x1
000632184 588__ $$aDataset connected to CrossRef, Journals: bib-pubdb1.desy.de
000632184 693__ $$0EXP:(DE-H253)P-P05-20150101$$1EXP:(DE-H253)PETRAIII-20150101$$6EXP:(DE-H253)P-P05-20150101$$aPETRA III$$fPETRA Beamline P05$$x0
000632184 7001_ $$0P:(DE-H253)PIP1107148$$aMaurer, Julia$$b1
000632184 7001_ $$0P:(DE-H253)PIP1107151$$aHeupl, Sarah$$b2
000632184 7001_ $$0P:(DE-H253)PIP1011753$$aWilde, Fabian$$b3
000632184 7001_ $$0P:(DE-H253)PIP1012991$$aTolnai, Domonkos$$b4
000632184 7001_ $$0P:(DE-H253)PIP1107550$$aKrenn, Stefan$$b5
000632184 7001_ $$0P:(DE-HGF)0$$aGebhardt, Klaus$$b6
000632184 7001_ $$0P:(DE-H253)PIP1108599$$aSiakkou, Eleni$$b7
000632184 7001_ $$00000-0002-4774-2963$$aBurgstaller, Christoph$$b8
000632184 7001_ $$00000-0002-5592-5364$$aArchodoulaki, Vasiliki-Maria$$b9
000632184 7001_ $$00009-0008-2812-0609$$aSchöbel, Michael$$b10
000632184 773__ $$0PERI:(DE-600)2012385-1$$a10.1016/j.compositesb.2025.112692$$gp. 112692 -$$p112692 $$tComposites / Part B$$v305$$x1359-8368$$y2025
000632184 8564_ $$uhttps://bib-pubdb1.desy.de/record/632184/files/1-s2.0-S1359836825005931-main.pdf$$yRestricted
000632184 8564_ $$uhttps://bib-pubdb1.desy.de/record/632184/files/1-s2.0-S1359836825005931-main.pdf?subformat=pdfa$$xpdfa$$yRestricted
000632184 909CO $$ooai:bib-pubdb1.desy.de:632184$$pVDB
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1107269$$aExternal Institute$$b0$$kExtern
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1107148$$aExternal Institute$$b1$$kExtern
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1107151$$aExternal Institute$$b2$$kExtern
000632184 9101_ $$0I:(DE-588b)16087541-9$$6P:(DE-H253)PIP1011753$$aHelmholtz-Zentrum Geesthacht$$b3$$kHZG
000632184 9101_ $$0I:(DE-588b)1231250402$$6P:(DE-H253)PIP1011753$$aHelmholtz-Zentrum Hereon$$b3$$kHereon
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1012991$$aExternal Institute$$b4$$kExtern
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1107550$$aExternal Institute$$b5$$kExtern
000632184 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1108599$$aExternal Institute$$b7$$kExtern
000632184 9131_ $$0G:(DE-HGF)POF4-6G3$$1G:(DE-HGF)POF4-6G0$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lGroßgeräte: Materie$$vPETRA III (DESY)$$x0
000632184 9141_ $$y2025
000632184 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bCOMPOS PART B-ENG : 2022$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)1160$$2StatID$$aDBCoverage$$bCurrent Contents - Engineering, Computing and Technology$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2024-12-11
000632184 915__ $$0StatID:(DE-HGF)9910$$2StatID$$aIF >= 10$$bCOMPOS PART B-ENG : 2022$$d2024-12-11
000632184 9201_ $$0I:(DE-H253)HAS-User-20120731$$kDOOR ; HAS-User$$lDOOR-User$$x0
000632184 9201_ $$0I:(DE-H253)Hereon-20210428$$kHereon$$lHelmholtz-Zentrum Hereon$$x1
000632184 980__ $$ajournal
000632184 980__ $$aVDB
000632184 980__ $$aI:(DE-H253)HAS-User-20120731
000632184 980__ $$aI:(DE-H253)Hereon-20210428
000632184 980__ $$aUNRESTRICTED