000625891 245__ $$aDosimetric and temporal beam characterization of individual pulses in FLASH radiotherapy using Timepix3 pixelated detector placed out-of-field
000625891 260__ $$aAmsterdam$$bElsevier$$c2025
000625891 3367_ $$2DRIVER$$aarticle
000625891 3367_ $$2DataCite$$aOutput Types/Journal article
000625891 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1745414376_3837419
000625891 3367_ $$2BibTeX$$aARTICLE
000625891 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000625891 3367_ $$00$$2EndNote$$aJournal Article
000625891 500__ $$aWaiting for fulltext
000625891 520__ $$aBackground: FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods used to measure the delivered number of pulses, investigate temporal structure of individual pulses and dose-per-pulse (DPP) based on secondary radiation particles produced in the experimental room. Methods: A 20 MeV electron beam generated from a linear accelerator (LINAC) was delivered to a water phantom. Ultra-high dose-per-pulse electron beams were used with a dose-per-pulse ranging from ~1 Gy to over 7 Gy. The pulse lengths ranged from 1.18 µs to 2.88 µs at a pulse rate frequency of 5 Hz. A semiconductor pixel detector Timepix3 was used to track single secondary particles. Measurements were performed in the air, while the detector was positioned out-of-field at a lateral distance of 200 cm parallel with the LINAC exit window. The dose deposited was measured along with the pulse length and the nanostructure of the pulse. Results:The time of arrival (ToA) of single particles was measured with a resolution of 1.56 ns, while the deposited energy was measured with a resolution of several keV based on the Time over Threshold (ToT) value. The pulse count measured by the Timepix3 detector corresponded with the delivered values, which were measured using an in-flange integrating current transformer (ICT). A linear response (R$^2$ = 0.999) was established between the delivered beam current and the measured dose at the detector position (orders of nGy). The difference between the average measured and delivered pulse length was ~0.003(30) μs. Conclusion: This simple non-invasive method exhibits no limitations on the delivered DPP within the range used during this investigation.
000625891 536__ $$0G:(DE-HGF)POF4-622$$a622 - Detector Technologies and Systems (POF4-622)$$cPOF4-622$$fPOF IV$$x0
000625891 588__ $$aDataset connected to CrossRef, Journals: bib-pubdb1.desy.de
000625891 693__ $$0EXP:(DE-H253)PITZ-20150101$$5EXP:(DE-H253)PITZ-20150101$$ePhoto Injector Test Facility$$x0
000625891 7001_ $$00009-0001-9374-2526$$aSykorova, Katerina$$b1
000625891 7001_ $$aJakubek, Jan$$b2
000625891 7001_ $$aPivec, Jiri$$b3
000625891 7001_ $$0P:(DE-H253)PIP1020058$$aRiemer, Felix$$b4
000625891 7001_ $$0P:(DE-H253)PIP1089976$$aWorm, Steven$$b5
000625891 7001_ $$00000-0001-6429-4122$$aBourgouin, Alexandra$$b6
000625891 773__ $$0PERI:(DE-600)2110535-2$$a10.1016/j.ejmp.2024.104872$$gVol. 129, p. 104872 -$$p104872$$tPhysica medica$$v129$$x1120-1797$$y2025
000625891 8564_ $$uhttps://bib-pubdb1.desy.de/record/625891/files/PIIS1120179724013401.pdf$$yRestricted
000625891 8564_ $$uhttps://bib-pubdb1.desy.de/record/625891/files/PIIS1120179724013401.pdf?subformat=pdfa$$xpdfa$$yRestricted
000625891 909CO $$ooai:bib-pubdb1.desy.de:625891$$pVDB
000625891 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1020058$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000625891 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1089976$$aDeutsches Elektronen-Synchrotron$$b5$$kDESY
000625891 9131_ $$0G:(DE-HGF)POF4-622$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vDetector Technologies and Systems$$x0
000625891 9141_ $$y2025
000625891 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2025-01-02$$wger
000625891 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bPHYS MEDICA : 2022$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)1110$$2StatID$$aDBCoverage$$bCurrent Contents - Clinical Medicine$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2025-01-02
000625891 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2025-01-02
000625891 9201_ $$0I:(DE-H253)Z_DET-20201126$$kZ_DET$$lZ_DET$$x0
000625891 980__ $$ajournal
000625891 980__ $$aVDB
000625891 980__ $$aI:(DE-H253)Z_DET-20201126
000625891 980__ $$aUNRESTRICTED