TY - JOUR
AU - Iori, Gianluca
AU - Alzu'bi, Mustafa
AU - Abbadi, Anas
AU - Al Momani, Yazeed
AU - Hasoneh, Abdel Rahman
AU - Van Vaerenbergh, Pierre
AU - Cudin, Ivan
AU - Marcos, Jordi
AU - Ahmad, Abdalla
AU - Mohammad, Anas
AU - Matalgah, Salman
AU - Foudeh, Ibrahim
AU - Al Najdawi, Mohammad
AU - Amro, Adel
AU - Ur Rehman, Abid
AU - Abugharbiyeh, Mohammad
AU - Khrais, Rami
AU - Aljadaa, Amro
AU - Nour, Mohammad
AU - Al Mohammad, Hussam
AU - Al Omari, Farouq
AU - Salama, Majeda
AU - García Fusté, María José
AU - Reyes-Herrera, Juan
AU - Morawe, Christian
AU - Attal, Maher
AU - Kasaei, Samira
AU - Chrysostomou, Charalambos
AU - Kołodziej, Tomasz
AU - Boruchowski, Mateusz
AU - Krisch, Michael
AU - Nowak, Paweł
AU - Wiechecki, Jarosław
AU - Fatima, Anis
AU - Ghigo, Andrea
AU - Wawrzyniak, Adriana I.
AU - Lorentz, Kirsi
AU - Paolucci, Giorgio
AU - Lehner, Frank
AU - Stampanoni, Marco
AU - Rack, Alexander
AU - Kaprolat, Axel
AU - Lausi, Andrea
TI - BEATS: BEAmline for synchrotron X-ray microTomography at SESAME
JO - Journal of synchrotron radiation
VL - 31
IS - 5
SN - 0909-0495
CY - Chester
PB - IUCr
M1 - PUBDB-2025-00283
SP - 1358 - 1372
PY - 2024
N1 - CCBY
AB - The ID10 beamline of the SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) synchrotron light source in Jordan was inaugurated in June 2023 and is now open to scientific users. The beamline, which was designed and installed within the European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS), provides full-field X-ray radiography and microtomography imaging with monochromatic or polychromatic X-rays up to photon energies of 100 keV. The photon source generated by a 2.9 T wavelength shifter with variable gap, and a double-multilayer monochromator system allow versatile application for experiments requiring either an X-ray beam with high intensity and flux, and/or a partially spatial coherent beam for phase-contrast applications. Sample manipulation and X-ray detection systems are designed to allow scanning samples with different size, weight and material, providing image voxel sizes from 13 µm down to 0.33 µm. A state-of-the-art computing infrastructure for data collection, three-dimensional (3D) image reconstruction and data analysis allows the visualization and exploration of results online within a few seconds from the completion of a scan. Insights from 3D X-ray imaging are key to the investigation of specimens from archaeology and cultural heritage, biology and health sciences, materials science and engineering, earth, environmental sciences and more. Microtomography scans and preliminary results obtained at the beamline demonstrate that the new beamline ID10-BEATS expands significantly the range of scientific applications that can be targeted at SESAME.
LB - PUB:(DE-HGF)16
C6 - pmid:39007825
DO - DOI:10.1107/S1600577524005277
UR - https://bib-pubdb1.desy.de/record/622245
ER -