000618774 001__ 618774
000618774 005__ 20250128223153.0
000618774 037__ $$aPUBDB-2024-07136
000618774 041__ $$aEnglish
000618774 1001_ $$0P:(DE-H253)PIP1092505$$aDe Silva, Malinda$$b0$$eCorresponding author$$udesy
000618774 1112_ $$a10th Matter and Technologies Meeting$$cBerlin$$wGermany
000618774 245__ $$aelectronCT - An Imaging Technique Using Very High Energy Electrons (VHEE)$$f2024-09-18 - 
000618774 260__ $$c2024
000618774 3367_ $$033$$2EndNote$$aConference Paper
000618774 3367_ $$2DataCite$$aOther
000618774 3367_ $$2BibTeX$$aINPROCEEDINGS
000618774 3367_ $$2ORCID$$aLECTURE_SPEECH
000618774 3367_ $$0PUB:(DE-HGF)31$$2PUB:(DE-HGF)$$aTalk (non-conference)$$btalk$$mtalk$$s1738061060_2514880$$xPlenary/Keynote
000618774 3367_ $$2DINI$$aOther
000618774 502__ $$cDESY
000618774 520__ $$aThe electronCT technique is a novel imaging method based on the multiple Coulomb scattering of electrons of energies in the range of 100 to 250 MeV.  One potential use case lies in the context of radiation therapy with “very-high energy electrons” or VHEE. This technique involves using a pencil beam of electrons and a single detection layer to determine the beam profile. Electron scattering within a sample results in a change in the beam profile. This change in profile is used to scan through the sample to reconstruct the 2D or 3D tomographic image of the sample. Given that electrons of similar energies are also used for VHEE-based radiotherapy, electronCT offers the potential to be used as an in-situ imaging method just before treatment. Measurements have been performed at the ARES linear particle accelerator at an electron energy of 155 MeV using multiple mouse phantoms as samples and a Timepix3 silicon pixel detector as the sensor to demonstrate the feasibility of the technique. Further simulation studies are currently being conducted using allpix squared simulation tool based on Geant4 to further validate this method and its effectiveness. Results from all these studies will be presented in this contribution.
000618774 536__ $$0G:(DE-HGF)POF4-622$$a622 - Detector Technologies and Systems (POF4-622)$$cPOF4-622$$fPOF IV$$x0
000618774 693__ $$0EXP:(DE-H253)ARES-20200101$$1EXP:(DE-H253)SINBAD-20200101$$5EXP:(DE-H253)ARES-20200101$$aSINBAD$$eAccelerator Research Experiment at SINBAD$$x0
000618774 7001_ $$0P:(DE-H253)PIP1108098$$aAbel, Aenne$$b1$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1080380$$aBurkart, Florian$$b2$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1021528$$aDinter, Hannes$$b3$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1107772$$aDojan, Kevin$$b4
000618774 7001_ $$0P:(DE-H253)PIP1031938$$aHerkert, Adrian$$b5$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1020401$$aJaster-Merz, Sonja Meike$$b6$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1086263$$aKellermeier, Max$$b7$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1030512$$aKuropka, Willi$$b8$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1014786$$aMayet, Frank$$b9$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1019945$$aSchütze, Paul$$b10$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1099054$$aRuiz Daza, Sara$$b11$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1018940$$aSpannagel, Simon$$b12$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1019775$$aVinatier, Thomas$$b13$$udesy
000618774 7001_ $$0P:(DE-H253)PIP1097675$$aWennloef, Hakan Lennart Olov$$b14$$udesy
000618774 8564_ $$uhttps://bib-pubdb1.desy.de/record/618774/files/electronCT.pdf$$yRestricted
000618774 8564_ $$uhttps://bib-pubdb1.desy.de/record/618774/files/electronCT.pdf?subformat=pdfa$$xpdfa$$yRestricted
000618774 909CO $$ooai:bib-pubdb1.desy.de:618774$$pVDB
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1092505$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000618774 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1092505$$aExternal Institute$$b0$$kExtern
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1108098$$aDeutsches Elektronen-Synchrotron$$b1$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1080380$$aDeutsches Elektronen-Synchrotron$$b2$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1021528$$aDeutsches Elektronen-Synchrotron$$b3$$kDESY
000618774 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1107772$$aExternal Institute$$b4$$kExtern
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1031938$$aDeutsches Elektronen-Synchrotron$$b5$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1020401$$aDeutsches Elektronen-Synchrotron$$b6$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1086263$$aDeutsches Elektronen-Synchrotron$$b7$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1030512$$aDeutsches Elektronen-Synchrotron$$b8$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1014786$$aDeutsches Elektronen-Synchrotron$$b9$$kDESY
000618774 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1014786$$aExternal Institute$$b9$$kExtern
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1019945$$aDeutsches Elektronen-Synchrotron$$b10$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1099054$$aDeutsches Elektronen-Synchrotron$$b11$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1018940$$aDeutsches Elektronen-Synchrotron$$b12$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1019775$$aDeutsches Elektronen-Synchrotron$$b13$$kDESY
000618774 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1097675$$aDeutsches Elektronen-Synchrotron$$b14$$kDESY
000618774 9131_ $$0G:(DE-HGF)POF4-622$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vDetector Technologies and Systems$$x0
000618774 9141_ $$y2024
000618774 9201_ $$0I:(DE-H253)ITT-20160816$$kITT$$lInnovation & Technologietransfer$$x0
000618774 9201_ $$0I:(DE-H253)CMS-20120731$$kCMS$$lLHC/CMS Experiment$$x1
000618774 980__ $$atalk
000618774 980__ $$aVDB
000618774 980__ $$aI:(DE-H253)ITT-20160816
000618774 980__ $$aI:(DE-H253)CMS-20120731
000618774 980__ $$aUNRESTRICTED