000615639 001__ 615639
000615639 005__ 20250808105125.0
000615639 0247_ $$2doi$$a10.1107/S1600577524006015
000615639 0247_ $$2ISSN$$a0909-0495
000615639 0247_ $$2ISSN$$a1600-5775
000615639 0247_ $$2datacite_doi$$a10.3204/PUBDB-2024-06216
000615639 0247_ $$2altmetric$$aaltmetric:165798522
000615639 0247_ $$2pmid$$apmid:39078693
000615639 0247_ $$2WOS$$aWOS:001362324700004
000615639 0247_ $$2openalex$$aopenalex:W4401116887
000615639 037__ $$aPUBDB-2024-06216
000615639 041__ $$aEnglish
000615639 082__ $$a550
000615639 1001_ $$0P:(DE-HGF)0$$aÇonka Yıldız, Tuba$$b0$$eCorresponding author
000615639 245__ $$aDiamond sensors for hard X-ray energy and position resolving measurements at the European XFEL
000615639 260__ $$a[Erscheinungsort nicht ermittelbar]$$bWiley-Blackwell$$c2024
000615639 3367_ $$2DRIVER$$aarticle
000615639 3367_ $$2DataCite$$aOutput Types/Journal article
000615639 3367_ $$0PUB:(DE-HGF)16$$2PUB:(DE-HGF)$$aJournal Article$$bjournal$$mjournal$$s1728980811_774761
000615639 3367_ $$2BibTeX$$aARTICLE
000615639 3367_ $$2ORCID$$aJOURNAL_ARTICLE
000615639 3367_ $$00$$2EndNote$$aJournal Article
000615639 520__ $$aThe diagnostics of X-ray beam properties has a critical importance at the European X-ray Free-Electron Laser facility. Besides existing diagnostic components, utilization of a diamond sensor was proposed to achieve radiation-hard, non-invasive beam position and pulse energy measurements for hard X-rays. In particular, with very hard X-rays, diamond-based sensors become a useful complement to gas-based devices which lose sensitivity due to significantly reduced gas cross-sections. The measurements presented in this work were performed with diamond sensors consisting of an electronic-grade single-crystal chemical-vapor-deposition diamond with position-sensitive resistive electrodes in a duo-lateral configuration. The results show that the diamond sensor delivers pulse-resolved X-ray beam position data at 2.25 MHz with an uncertainty of less than 1% of the beam size. To our knowledge this is the first demonstration of pulse-resolved position measurements at the MHz rate using a transmissive diamond sensor at a free-electron laser facility. It can therefore be a valuable tool for X-ray free-electron lasers, especially for high-repetition-rate machines, enabling applications such as beam-based alignment and intra-pulse-train position feedback.
000615639 536__ $$0G:(DE-HGF)POF4-6G13$$a6G13 - Accelerator of European XFEL (POF4-6G13)$$cPOF4-6G13$$fPOF IV$$x0
000615639 542__ $$2Crossref$$i2024-07-30$$uhttps://creativecommons.org/licenses/by/4.0/legalcode
000615639 542__ $$2Crossref$$i2024-07-30$$uhttps://creativecommons.org/licenses/by/4.0/legalcode
000615639 588__ $$aDataset connected to CrossRef, Journals: bib-pubdb1.desy.de
000615639 693__ $$0EXP:(DE-H253)XFEL-Exp-20150101$$1EXP:(DE-H253)XFEL-20150101$$5EXP:(DE-H253)XFEL-Exp-20150101$$aXFEL$$eExperiments at XFEL$$x0
000615639 7001_ $$aFreund, Wolfgang$$b1
000615639 7001_ $$0P:(DE-H253)PIP1019426$$aLiu, Jia$$b2
000615639 7001_ $$aSchreck, Matthias$$b3
000615639 7001_ $$aKhakhulin, Dmitry$$b4
000615639 7001_ $$aYousef, Hazem$$b5
000615639 7001_ $$aMilne, Christopher$$b6
000615639 7001_ $$aGrünert, Jan$$b7
000615639 77318 $$2Crossref$$3journal-article$$a10.1107/s1600577524006015$$bInternational Union of Crystallography (IUCr)$$d2024-07-30$$n5$$p1029-1036$$tJournal of Synchrotron Radiation$$v31$$x1600-5775$$y2024
000615639 773__ $$0PERI:(DE-600)2021413-3$$a10.1107/S1600577524006015$$gVol. 31, no. 5, p. 1029 - 1036$$n5$$p1029-1036$$tJournal of synchrotron radiation$$v31$$x1600-5775$$y2024
000615639 8564_ $$uhttps://bib-pubdb1.desy.de/record/615639/files/uy5001.pdf$$yOpenAccess
000615639 8564_ $$uhttps://bib-pubdb1.desy.de/record/615639/files/uy5001.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000615639 8767_ $$92024-02-08$$a52909350$$d2024-10-09$$eAPC$$jDEAL$$lWiley$$v6.92$$zXFEL gold oa: Einzelnachweis Rechnung W-2024-00978-b
000615639 8767_ $$92025$$d2024-10-09$$ePayment fee$$jDEAL$$lWiley$$v0.35$$zMPDL Gebühr
000615639 8767_ $$92024-02-08$$a52909350$$d2024-10-09$$eAPC$$jStorniert$$lWiley$$zDFG OAPK (Projekt)
000615639 8767_ $$92024-02-08$$a52909350$$d2024-10-09$$eAPC$$jZahlung erfolgt$$lWiley$$zDFG OAPK (Projekt)
000615639 909CO $$ooai:bib-pubdb1.desy.de:615639$$pdnbdelivery$$popenCost$$pVDB$$pdriver$$pOpenAPC$$popen_access$$popenaire
000615639 9101_ $$0I:(DE-588)1043621512$$6P:(DE-H253)PIP1019426$$aEuropean XFEL$$b2$$kXFEL.EU
000615639 9131_ $$0G:(DE-HGF)POF4-6G13$$1G:(DE-HGF)POF4-6G0$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lGroßgeräte: Materie$$vAccelerator of European XFEL$$x0
000615639 9141_ $$y2024
000615639 915__ $$0StatID:(DE-HGF)0160$$2StatID$$aDBCoverage$$bEssential Science Indicators$$d2023-08-29
000615639 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000615639 915__ $$0StatID:(DE-HGF)3001$$2StatID$$aDEAL Wiley$$d2023-08-29$$wger
000615639 915__ $$0StatID:(DE-HGF)0501$$2StatID$$aDBCoverage$$bDOAJ Seal$$d2023-03-08T13:56:53Z
000615639 915__ $$0StatID:(DE-HGF)0500$$2StatID$$aDBCoverage$$bDOAJ$$d2023-03-08T13:56:53Z
000615639 915__ $$0StatID:(DE-HGF)0113$$2StatID$$aWoS$$bScience Citation Index Expanded$$d2023-08-29
000615639 915__ $$0StatID:(DE-HGF)0700$$2StatID$$aFees$$d2023-08-29
000615639 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000615639 915__ $$0StatID:(DE-HGF)0561$$2StatID$$aArticle Processing Charges$$d2023-08-29
000615639 915__ $$0StatID:(DE-HGF)0420$$2StatID$$aNationallizenz$$d2025-01-06$$wger
000615639 915__ $$0StatID:(DE-HGF)0100$$2StatID$$aJCR$$bJ SYNCHROTRON RADIAT : 2022$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0200$$2StatID$$aDBCoverage$$bSCOPUS$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0300$$2StatID$$aDBCoverage$$bMedline$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bDOAJ : Anonymous peer review$$d2023-03-08T13:56:53Z
000615639 915__ $$0StatID:(DE-HGF)0600$$2StatID$$aDBCoverage$$bEbsco Academic Search$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0030$$2StatID$$aPeer Review$$bASC$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0199$$2StatID$$aDBCoverage$$bClarivate Analytics Master Journal List$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)1150$$2StatID$$aDBCoverage$$bCurrent Contents - Physical, Chemical and Earth Sciences$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)0150$$2StatID$$aDBCoverage$$bWeb of Science Core Collection$$d2025-01-06
000615639 915__ $$0StatID:(DE-HGF)9900$$2StatID$$aIF < 5$$d2025-01-06
000615639 915pc $$0PC:(DE-HGF)0000$$2APC$$aAPC keys set
000615639 915pc $$0PC:(DE-HGF)0001$$2APC$$aLocal Funding
000615639 915pc $$0PC:(DE-HGF)0002$$2APC$$aDFG OA Publikationskosten
000615639 915pc $$0PC:(DE-HGF)0120$$2APC$$aDEAL: Wiley 2019
000615639 915pc $$0PC:(DE-HGF)0003$$2APC$$aDOAJ Journal
000615639 9201_ $$0I:(DE-H253)XFEL_DO_ID_XPD-20210408$$kXFEL_DO_ID_XPD$$lX-Ray Photon Diagnostics$$x0
000615639 980__ $$ajournal
000615639 980__ $$aVDB
000615639 980__ $$aUNRESTRICTED
000615639 980__ $$aI:(DE-H253)XFEL_DO_ID_XPD-20210408
000615639 980__ $$aAPC
000615639 9801_ $$aAPC
000615639 9801_ $$aFullTexts
000615639 999C5 $$2Crossref$$uBloomer, C., Bobb, L., Newton, M. E., Freund, W., Grünert, J. & Liu, J. (2022). Proceedings of the 11th International Beam Instrumentation Conference (IBIC 2022), 11-15 September 2022, Krakow, Poland, pp. 416-420. WEP15.
000615639 999C5 $$1Bohon$$2Crossref$$9-- missing cx lookup --$$a10.1107/S0909049510031420$$p711 -$$tJ. Synchrotron Rad.$$v17$$y2010
000615639 999C5 $$1Çonka Yıldız$$2Crossref$$9-- missing cx lookup --$$a10.1364/OPTICA.495437$$p963 -$$tOptica$$v10$$y2023
000615639 999C5 $$1Decking$$2Crossref$$9-- missing cx lookup --$$a10.1038/s41566-020-0607-z$$p391 -$$tNat. Photon.$$v14$$y2020
000615639 999C5 $$1Desjardins$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577517016769$$p399 -$$tJ. Synchrotron Rad.$$v25$$y2018
000615639 999C5 $$1Freund$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577519005307$$p1037 -$$tJ. Synchrotron Rad.$$v26$$y2019
000615639 999C5 $$1Galler$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577519006647$$p1432 -$$tJ. Synchrotron Rad.$$v26$$y2019
000615639 999C5 $$1Grünert$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577519006611$$p1422 -$$tJ. Synchrotron Rad.$$v26$$y2019
000615639 999C5 $$1Koch$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577519008737$$p1489 -$$tJ. Synchrotron Rad.$$v26$$y2019
000615639 999C5 $$1Maltezopoulos$$2Crossref$$9-- missing cx lookup --$$a10.1107/S160057752400331X$$p681 -$$tJ. Synchrotron Rad.$$v31$$y2024
000615639 999C5 $$1Maltezopoulos$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577519003795$$p1045 -$$tJ. Synchrotron Rad.$$v26$$y2019
000615639 999C5 $$1Morse$$2Crossref$$9-- missing cx lookup --$$a10.1107/S0909049510016547$$p456 -$$tJ. Synchrotron Rad.$$v17$$y2010
000615639 999C5 $$1Pomorski$$2Crossref$$9-- missing cx lookup --$$a10.1002/pssa.200982229$$p2109 -$$tPhys. Status Solidi A$$v206$$y2009
000615639 999C5 $$1Roth$$2Crossref$$9-- missing cx lookup --$$a10.1107/S1600577517015016$$p177 -$$tJ. Synchrotron Rad.$$v25$$y2018
000615639 999C5 $$1Tono$$2Crossref$$9-- missing cx lookup --$$a10.1063/1.3549133$$p023108 -$$tRev. Sci. Instrum.$$v82$$y2011