001     603182
005     20240306210547.0
037 _ _ |a PUBDB-2024-00819
041 _ _ |a English
100 1 _ |a Lamaack, Jonas
|0 P:(DE-H253)PIP1105411
|b 0
|e Corresponding author
|g male
245 _ _ |a New Beam Position Monitor System for PETRA IV
|f 2023-07-01 - 2024-02-01
260 _ _ |c 2024
300 _ _ |a 41
336 7 _ |a bachelorThesis
|2 DRIVER
336 7 _ |a Thesis
|0 2
|2 EndNote
336 7 _ |a Output Types/Supervised Student Publication
|2 DataCite
336 7 _ |a Bachelor Thesis
|b bachelor
|m bachelor
|0 PUB:(DE-HGF)2
|s 1709720303_3370032
|2 PUB:(DE-HGF)
336 7 _ |a MASTERSTHESIS
|2 BibTeX
336 7 _ |a SUPERVISED_STUDENT_PUBLICATION
|2 ORCID
502 _ _ |a Bachelorarbeit, University of Hamburg, 2024
|c University of Hamburg
|b Bachelorarbeit
|d 2024
|o 2024-01-15
520 _ _ |a The PETRA IV project at DESY aims to upgrade the present synchrotron radiation sourcePETRA III into a source of ultra-low emittance with target emittance of 20pmrad. Thesmall beam emittance translates directly into much smaller beam sizes of about 7 μmhorizontally and 3 μm vertically at insertion device source points, thus imposing stringentrequirements on the machine’s stability. To measure beam position and control orbitstability to the required level of accuracy, a high-resolution BPM system consisting ofapprox. 800 individual monitors will be installed. Its readout electronics will be based onMTCA.4 as a technical platform. To fulfill the long-term drift requirement (< 1 μm over 6days), the concept of crossbar-switching was extended in a way that the analog RF switchmatrix is separated from the readout electronics and placed as close to the BPM pickupas possible, therefore enabling the stabilization of the RF cables. A new RTM card withseveral analog and digital parts taken from the Libera Brilliance+ has been developed andis currently used as the BPM electronic front end. At present, a fully populated MTCAcrate with 6 2BPMRTM and 6 commercial AMC boards for the readout of 12 BPMs isinstalled at PETRA III. This thesis is a performance evaluation of the new system andsummarizes the latest beam measurements, showing that the performance requirementsfor PETRA IV are met.
536 _ _ |a 621 - Accelerator Research and Development (POF4-621)
|0 G:(DE-HGF)POF4-621
|c POF4-621
|f POF IV
|x 0
693 _ _ |a PETRA III
|e Facility (machine) PETRA III
|1 EXP:(DE-H253)PETRAIII-20150101
|0 EXP:(DE-H253)PETRAIII(machine)-20150101
|5 EXP:(DE-H253)PETRAIII(machine)-20150101
|x 0
693 _ _ |1 EXP:(DE-H253)PETRAIV-20220101
|0 EXP:(DE-H253)PETRAIV-20220101
|a PETRA IV
|x 1
700 1 _ |a Hillert, Wolfgang
|0 P:(DE-H253)PIP1032393
|b 1
|e Thesis advisor
700 1 _ |a Kube, Gero
|0 P:(DE-H253)PIP1002168
|b 2
|e Thesis advisor
|u desy
856 4 _ |u https://bib-pubdb1.desy.de/record/603182/files/BSc_Thesis_Lamaack_New_BPM_System_for_PETRA_IV_V2.pdf
|y Restricted
856 4 _ |u https://bib-pubdb1.desy.de/record/603182/files/BSc_Thesis_Lamaack_New_BPM_System_for_PETRA_IV_V2.pdf?subformat=pdfa
|x pdfa
|y Restricted
909 C O |o oai:bib-pubdb1.desy.de:603182
|p VDB
910 1 _ |a External Institute
|0 I:(DE-HGF)0
|k Extern
|b 0
|6 P:(DE-H253)PIP1105411
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 1
|6 P:(DE-H253)PIP1032393
910 1 _ |a External Institute
|0 I:(DE-HGF)0
|k Extern
|b 1
|6 P:(DE-H253)PIP1032393
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 2
|6 P:(DE-H253)PIP1002168
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Materie und Technologie
|1 G:(DE-HGF)POF4-620
|0 G:(DE-HGF)POF4-621
|3 G:(DE-HGF)POF4
|2 G:(DE-HGF)POF4-600
|4 G:(DE-HGF)POF
|v Accelerator Research and Development
|x 0
914 1 _ |y 2024
920 _ _ |l yes
920 1 _ |0 I:(DE-H253)MDI-20120806
|k MDI
|l Diagnose und Instrumentierung
|x 0
980 _ _ |a bachelor
980 _ _ |a VDB
980 _ _ |a I:(DE-H253)MDI-20120806
980 _ _ |a UNRESTRICTED


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21