000588904 001__ 588904
000588904 005__ 20231117212527.0
000588904 020__ $$a978-3-95450-234-9
000588904 0247_ $$2doi$$a10.18429/JACoW-SRF2023-TUPTB037
000588904 0247_ $$2datacite_doi$$a10.3204/PUBDB-2023-05028
000588904 037__ $$aPUBDB-2023-05028
000588904 041__ $$aEnglish
000588904 1001_ $$0P:(DE-H253)PIP1093055$$aTrelle, Lennart$$b0$$eCorresponding author
000588904 1112_ $$a21st International Conference on Radio-Frequency Superconductivity$$cGrand Rapids$$d2023-06-25 - 2023-06-30$$gSRF2023$$wUSA
000588904 245__ $$aRefurbishment and Reactivation of a Niobium Retort Furnace at DESY
000588904 260__ $$aGeneva, Switzerland$$bJACoW Publishing$$c2023
000588904 29510 $$a[Ebook] 21st International Conference on RF Superconductivity, 25-30 June 2023, Amway Grand Plaza Hotel, Grand Rapids, Michigan, USA : proceedings / Gibbs, Sumner , [Geneva] : JACoW Publishing, [2023],
000588904 300__ $$a485-489
000588904 3367_ $$2ORCID$$aCONFERENCE_PAPER
000588904 3367_ $$033$$2EndNote$$aConference Paper
000588904 3367_ $$2BibTeX$$aINPROCEEDINGS
000588904 3367_ $$2DRIVER$$aconferenceObject
000588904 3367_ $$2DataCite$$aOutput Types/Conference Paper
000588904 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1700224650_3788313
000588904 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$mcontb
000588904 500__ $$aLiteraturangaben;
000588904 520__ $$aFor research in the field of heat treatments of superconducting cavities, a niobium ultra-high vacuum furnace built in 1992 – originally used for the titanization of 1.3 GHz nine-cell cavities – and later shut down was recently refurbished and reactivated. A significant upgrade is the ability to run the furnace in partial pressure mode with nitrogen. The furnace is connected directly to the ISO4 area ofthe clean room for cavity handling. At room temperature vacuum values of around 3×10-8 mbar are achieved. The revision included the replacement of the complete control system and a partial renewal of the pump technology. The internal mounting structures are optimized for single-cell operation including tandem operation (two single-cell cavities at once) and corresponding accessories such aswitness-samples and caps for the cavities. The installation of additional thermocouples for a detailed monitoring of the temperature curves is also possible at the mounting structure. Due to the furnace design, its location and the strict routines in handling, very high purity levels are achieved in comparison to similar set-ups and hence provide a mighty tool for SRF cavity R&D at DESY.
000588904 536__ $$0G:(DE-HGF)POF4-621$$a621 - Accelerator Research and Development (POF4-621)$$cPOF4-621$$fPOF IV$$x0
000588904 588__ $$aDataset connected to DataCite
000588904 650_7 $$2Other$$aAccelerator Physics
000588904 650_7 $$2Other$$aSRF Technology
000588904 693__ $$0EXP:(DE-H253)SRF-RD-20221201$$5EXP:(DE-H253)SRF-RD-20221201$$eSuperconductivity Radio Frequency Research and Development$$x0
000588904 7001_ $$0P:(DE-H253)PIP1033383$$aBate, Christopher$$b1
000588904 7001_ $$0P:(DE-H253)PIP1001636$$aRemde, Helmut$$b2
000588904 7001_ $$0P:(DE-H253)PIP1001641$$aReschke, Detlef$$b3
000588904 7001_ $$0P:(DE-H253)PIP1001671$$aSchaffran, Joern$$b4
000588904 7001_ $$0P:(DE-H253)PIP1006596$$aSteder, Lea$$b5
000588904 7001_ $$0P:(DE-H253)PIP1003054$$aWeise, Hans$$b6
000588904 773__ $$a10.18429/JACoW-SRF2023-TUPTB037
000588904 8564_ $$uhttps://bib-pubdb1.desy.de/record/588904/files/HTML-Approval_of_scientific_publication.html
000588904 8564_ $$uhttps://bib-pubdb1.desy.de/record/588904/files/PDF-Approval_of_scientific_publication.pdf
000588904 8564_ $$uhttps://bib-pubdb1.desy.de/record/588904/files/tuptb037.pdf$$yOpenAccess
000588904 8564_ $$uhttps://bib-pubdb1.desy.de/record/588904/files/tuptb037.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000588904 909CO $$ooai:bib-pubdb1.desy.de:588904$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1093055$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1033383$$aDeutsches Elektronen-Synchrotron$$b1$$kDESY
000588904 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1033383$$aExternal Institute$$b1$$kExtern
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001636$$aDeutsches Elektronen-Synchrotron$$b2$$kDESY
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001641$$aDeutsches Elektronen-Synchrotron$$b3$$kDESY
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001671$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1006596$$aDeutsches Elektronen-Synchrotron$$b5$$kDESY
000588904 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1003054$$aDeutsches Elektronen-Synchrotron$$b6$$kDESY
000588904 9131_ $$0G:(DE-HGF)POF4-621$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vAccelerator Research and Development$$x0
000588904 9141_ $$y2023
000588904 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000588904 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000588904 9201_ $$0I:(DE-H253)MSL-20170609$$kMSL$$lSupraleitende Beschleuniger Technologie$$x0
000588904 980__ $$acontrib
000588904 980__ $$aVDB
000588904 980__ $$aUNRESTRICTED
000588904 980__ $$acontb
000588904 980__ $$aI:(DE-H253)MSL-20170609
000588904 9801_ $$aFullTexts