000588898 001__ 588898
000588898 005__ 20240222165853.0
000588898 037__ $$aPUBDB-2023-05022
000588898 041__ $$aEnglish
000588898 1001_ $$0P:(DE-H253)PIP1093055$$aTrelle, Lennart$$b0$$eCorresponding author
000588898 1112_ $$a21st International Conference on Radio-Frequency Superconductivity$$cGrand Rapids$$d2023-06-25 - 2023-06-30$$gSRF2023$$wUSA
000588898 245__ $$aRefurbishment and Reactivation of a Niobium Retort Furnace at DESY
000588898 260__ $$c2023
000588898 3367_ $$033$$2EndNote$$aConference Paper
000588898 3367_ $$2BibTeX$$aINPROCEEDINGS
000588898 3367_ $$2DRIVER$$aconferenceObject
000588898 3367_ $$2ORCID$$aCONFERENCE_POSTER
000588898 3367_ $$2DataCite$$aOutput Types/Conference Poster
000588898 3367_ $$0PUB:(DE-HGF)24$$2PUB:(DE-HGF)$$aPoster$$bposter$$mposter$$s1708617427_3691546
000588898 520__ $$aFor research in the field of heat treatments of superconducting cavities, a niobium ultra-high vacuum furnace built in 1992 – originally used for the titanization of 1.3 GHz nine-cell cavities – and later shut down was recently refurbished and reactivated. A significant upgrade is the ability to run the furnace in partial pressure mode with nitrogen. The furnace is connected directly to the ISO4 area of the clean room for cavity handling. At room temperature vacuum values of around 3×10-8 mbar are achieved. The revision included the replacement of the complete control system and a partial renewal of the pump technology. The internal mounting structures are optimized for single-cell operation including tandem operation (two single-cell cavities at once) and corresponding accessories such as witness-samples and caps for the cavities. The installation of additional thermocouples for a detailed monitoring of the temperature curves is also possible at the mounting structure. Due to the furnace design, its location and the strict routines in handling, very high purity levels are achieved in comparison to similar set-ups and hence provide a mighty tool for SRF cavity R&D at DESY.
000588898 536__ $$0G:(DE-HGF)POF4-621$$a621 - Accelerator Research and Development (POF4-621)$$cPOF4-621$$fPOF IV$$x0
000588898 588__ $$aDataset connected to DataCite
000588898 650_7 $$2Other$$aAccelerator Physics
000588898 650_7 $$2Other$$aSRF Technology
000588898 693__ $$0EXP:(DE-H253)SRF-RD-20221201$$5EXP:(DE-H253)SRF-RD-20221201$$eSuperconductivity Radio Frequency Research and Development$$x0
000588898 7001_ $$0P:(DE-H253)PIP1033383$$aBate, Christopher$$b1$$udesy
000588898 7001_ $$0P:(DE-H253)PIP1001636$$aRemde, Helmut$$b2$$udesy
000588898 7001_ $$0P:(DE-H253)PIP1001641$$aReschke, Detlef$$b3$$udesy
000588898 7001_ $$0P:(DE-H253)PIP1001671$$aSchaffran, Joern$$b4$$udesy
000588898 7001_ $$0P:(DE-H253)PIP1006596$$aSteder, Lea$$b5$$udesy
000588898 7001_ $$0P:(DE-H253)PIP1003054$$aWeise, Hans$$b6$$udesy
000588898 7870_ $$0PUBDB-2023-05028$$aTrelle, Lennart et.al.$$dJACoW Publishing, Geneva, Switzerland, 2023$$iIsMemberOf$$r$$tRefurbishment and Reactivation of a Niobium Retort Furnace at DESY
000588898 8564_ $$uhttps://bib-pubdb1.desy.de/record/588898/files/HTML-Approval_of_scientific_publication.html
000588898 8564_ $$uhttps://bib-pubdb1.desy.de/record/588898/files/PDF-Approval_of_scientific_publication.pdf
000588898 8564_ $$uhttps://bib-pubdb1.desy.de/record/588898/files/TUPTB037_poster.pdf$$yRestricted
000588898 8564_ $$uhttps://bib-pubdb1.desy.de/record/588898/files/TUPTB037_poster.pdf?subformat=pdfa$$xpdfa$$yRestricted
000588898 909CO $$ooai:bib-pubdb1.desy.de:588898$$pVDB
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1093055$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1033383$$aDeutsches Elektronen-Synchrotron$$b1$$kDESY
000588898 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1033383$$aExternal Institute$$b1$$kExtern
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001636$$aDeutsches Elektronen-Synchrotron$$b2$$kDESY
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001641$$aDeutsches Elektronen-Synchrotron$$b3$$kDESY
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001671$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1006596$$aDeutsches Elektronen-Synchrotron$$b5$$kDESY
000588898 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1003054$$aDeutsches Elektronen-Synchrotron$$b6$$kDESY
000588898 9131_ $$0G:(DE-HGF)POF4-621$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vAccelerator Research and Development$$x0
000588898 9141_ $$y2023
000588898 9201_ $$0I:(DE-H253)MSL-20170609$$kMSL$$lSupraleitende Beschleuniger Technologie$$x0
000588898 980__ $$aposter
000588898 980__ $$aVDB
000588898 980__ $$aI:(DE-H253)MSL-20170609
000588898 980__ $$aUNRESTRICTED