000581968 001__ 581968
000581968 005__ 20231115211034.0
000581968 020__ $$a978-3-95450-231-8
000581968 0247_ $$2doi$$a10.18429/JACOW-IPAC2023-MOPA155
000581968 0247_ $$2datacite_doi$$a10.3204/PUBDB-2023-01718
000581968 037__ $$aPUBDB-2023-01718
000581968 041__ $$aEnglish
000581968 1001_ $$0P:(DE-H253)PIP1001362$$aWanzenberg, Rainer$$b0$$eCorresponding author
000581968 1112_ $$a14th International Particle Accelerator Conference$$cVenice$$d2023-05-07 - 2023-05-12$$gIPAC2023$$wItaly
000581968 245__ $$aPETRA III Operation and Studies in 2022
000581968 260__ $$a[Geneva]$$bJACoW Publishing$$c2023
000581968 29510 $$a[Ebook] IPAC'23 : 14th International Particle Accelerator Conference, 7-12 May 2023, Venice, Italy : proceedings / hosting institutions: INFN, Elettra Sincotrone Trieste , [Geneva] : JACoW Publishing, [2023],
000581968 300__ $$a415-417
000581968 3367_ $$2ORCID$$aCONFERENCE_PAPER
000581968 3367_ $$033$$2EndNote$$aConference Paper
000581968 3367_ $$2BibTeX$$aINPROCEEDINGS
000581968 3367_ $$2DRIVER$$aconferenceObject
000581968 3367_ $$2DataCite$$aOutput Types/Conference Paper
000581968 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1700038923_16728
000581968 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$mcontb
000581968 500__ $$aLiteraturangaben;
000581968 520__ $$aThe Synchrotron Light Source PETRA III is one of the core facilities at DESY offering each yearmore than 2000 users unique opportunities for experiments with hard X-rays of a very highbrilliance. The light source is operated mainly in two operation modes with 480 and 40 bunches at a beam energy of 6 GeV. The availability and failure statistics is reviewed for the year 2022 in comparison with previous years. Studies at PETRA III are supporting the technical design phase for the planned upgrade PETRA IV. Several diagnostic devices have been tested and the installation of a cavity has been prepared. Furthermore, the operation of PETRA III at 5 GeV has been studied with the goal to reduce the electric power consumption of the accelerator. But a 5 GeV test run for all beam lines at PETRA III showed that this operation mode is impairing the experimental opportunities due to the lower brilliance and photon flux for hard X-rays.
000581968 536__ $$0G:(DE-HGF)POF4-621$$a621 - Accelerator Research and Development (POF4-621)$$cPOF4-621$$fPOF IV$$x0
000581968 536__ $$0G:(DE-HGF)POF4-6G3$$a6G3 - PETRA III (DESY) (POF4-6G3)$$cPOF4-6G3$$fPOF IV$$x1
000581968 588__ $$aDataset connected to DataCite
000581968 650_7 $$2Other$$aAccelerator Physics
000581968 650_7 $$2Other$$amc2-photon-sources-and-electron-accelerators - MC2: Photon Sources and Electron Accelerators
000581968 650_7 $$2Other$$amc2-a05-synchrotron-radiation-facilities - MC2.A05: Synchrotron Radiation Facilities
000581968 693__ $$0EXP:(DE-H253)PETRAIII(machine)-20150101$$1EXP:(DE-H253)PETRAIII-20150101$$5EXP:(DE-H253)PETRAIII(machine)-20150101$$aPETRA III$$eFacility (machine) PETRA III$$x0
000581968 7001_ $$0P:(DE-H253)PIP1002918$$aBieler, Michael$$b1
000581968 7001_ $$0P:(DE-H253)PIP1002277$$aKeil, Joachim$$b2
000581968 7001_ $$0P:(DE-H253)PIP1003493$$aSahoo, Gajendra Kumar$$b3
000581968 7001_ $$0P:(DE-H253)PIP1096551$$aSchaumann, Michaela$$b4
000581968 773__ $$a10.18429/JACOW-IPAC2023-MOPA155
000581968 7870_ $$0PUBDB-2022-07160$$aBieler, Michael et.al.$$d2023$$iIsMemberOf$$tPETRA III Operation and Studies in 2022
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/HTML-Approval_of_scientific_publication.html
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/MOPA155.pdf$$yOpenAccess$$zStatID:(DE-HGF)0510
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/PDF-Approval_of_scientific_publication.pdf
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/MOPA155.2.pdf$$yRestricted$$zStatID:(DE-HGF)0599
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/MOPA155.pdf?subformat=pdfa$$xpdfa$$yOpenAccess$$zStatID:(DE-HGF)0510
000581968 8564_ $$uhttps://bib-pubdb1.desy.de/record/581968/files/MOPA155.2.pdf?subformat=pdfa$$xpdfa$$yRestricted$$zStatID:(DE-HGF)0599
000581968 909CO $$ooai:bib-pubdb1.desy.de:581968$$popenaire$$popen_access$$pVDB$$pdriver$$pdnbdelivery
000581968 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1001362$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000581968 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1002918$$aDeutsches Elektronen-Synchrotron$$b1$$kDESY
000581968 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1002277$$aDeutsches Elektronen-Synchrotron$$b2$$kDESY
000581968 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1003493$$aDeutsches Elektronen-Synchrotron$$b3$$kDESY
000581968 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1096551$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000581968 9131_ $$0G:(DE-HGF)POF4-621$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vAccelerator Research and Development$$x0
000581968 9131_ $$0G:(DE-HGF)POF4-6G3$$1G:(DE-HGF)POF4-6G0$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lGroßgeräte: Materie$$vPETRA III (DESY)$$x1
000581968 9141_ $$y2023
000581968 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000581968 915__ $$0LIC:(DE-HGF)CCBY4$$2HGFVOC$$aCreative Commons Attribution CC BY 4.0
000581968 9201_ $$0I:(DE-H253)MPE-20120731$$kMPE$$lPETRA$$x0
000581968 980__ $$acontrib
000581968 980__ $$aVDB
000581968 980__ $$aUNRESTRICTED
000581968 980__ $$acontb
000581968 980__ $$aI:(DE-H253)MPE-20120731
000581968 9801_ $$aFullTexts