000491583 001__ 491583
000491583 005__ 20240112092939.0
000491583 0247_ $$2INSPIRETeX$$aAugustin:2022xlh
000491583 0247_ $$2inspire$$ainspire:2616301
000491583 0247_ $$2arXiv$$aarXiv:2212.10248
000491583 0247_ $$2altmetric$$aaltmetric:140376678
000491583 037__ $$aPUBDB-2023-00275
000491583 041__ $$aEnglish
000491583 088__ $$2arXiv$$aarXiv:2212.10248
000491583 082__ $$a530
000491583 1001_ $$aAugustin, Heiko$$b0
000491583 245__ $$aTelePix – A fast region of interest trigger and timing layer for the EUDET Telescopes
000491583 260__ $$c2023
000491583 3367_ $$0PUB:(DE-HGF)25$$2PUB:(DE-HGF)$$aPreprint$$bpreprint$$mpreprint$$s1673948422_3128
000491583 3367_ $$2ORCID$$aWORKING_PAPER
000491583 3367_ $$028$$2EndNote$$aElectronic Article
000491583 3367_ $$2DRIVER$$apreprint
000491583 3367_ $$2BibTeX$$aARTICLE
000491583 3367_ $$2DataCite$$aOutput Types/Working Paper
000491583 500__ $$aPreprint submitted to Proceedings of the 15th Pisa Meeting on Advanced Detectors
000491583 520__ $$aTest beam facilities are essential to study the response of novel detectors to particles. At the DESY II Test Beam facility, users can test their detectors with an electron beam with a momentum from 1–6 GeV. To track the beam particles, EUDET-style telescopes are provided in each beam area. They provide excellent spatial resolution, but the time resolution is limited by the rolling shutter architecture to a precision of approximately 230 μs. Since the demand on particle rates – and hence track multiplicities – is increasing timing is becoming more relevant. DESY foresees several upgrades of the telescopes. TelePix is an upgrade project to provide track timestamping with a precision of better than 5 ns and a configurable region of interest to trigger the telescope readout. Small scale prototypes have been characterized in laboratory and test beam measurements. Laboratory tests with an injection corresponding to 2300 electrons show a S/N of above 20. Test beam characterization shows efficiencies of above 99% over a threshold range of more than 100 mV and time resolutions of 2.4 ns at low noise rates.
000491583 536__ $$0G:(DE-HGF)POF4-622$$a622 - Detector Technologies and Systems (POF4-622)$$cPOF4-622$$fPOF IV$$x0
000491583 588__ $$aDataset connected to CrossRef, INSPIRE, Journals: bib-pubdb1.desy.de
000491583 650_7 $$2autogen$$aHV-MAPS
000491583 650_7 $$2autogen$$aHV-CMOS
000491583 650_7 $$2autogen$$aTiming/trigger layer
000491583 650_7 $$2autogen$$atest beam
000491583 650_7 $$2autogen$$aTelescopes
000491583 693__ $$0EXP:(DE-H253)TestBeamline21-20150101$$1EXP:(DE-H253)DESYII-20150101$$6EXP:(DE-H253)TestBeamline21-20150101$$aDESY II$$fDESY: TestBeamline 21$$x0
000491583 693__ $$0EXP:(DE-H253)TestBeamline22-20150101$$1EXP:(DE-H253)DESYII-20150101$$6EXP:(DE-H253)TestBeamline22-20150101$$aDESY II$$fDESY: TestBeamline 22$$x1
000491583 693__ $$0EXP:(DE-H253)TestBeamline24-20150101$$1EXP:(DE-H253)DESYII-20150101$$6EXP:(DE-H253)TestBeamline24-20150101$$aDESY II$$fDESY: TestBeamline 24$$x2
000491583 7001_ $$aDittmeier, Sebastian$$b1
000491583 7001_ $$aHammerich, Jan$$b2
000491583 7001_ $$0P:(DE-H253)PIP1031938$$aHerkert, Adrian$$b3$$udesy
000491583 7001_ $$0P:(DE-H253)PIP1024990$$aHuth, Lennart$$b4$$eCorresponding author
000491583 7001_ $$aImmig, David$$b5
000491583 7001_ $$aPerić, Ivan$$b6
000491583 7001_ $$aSchöning, André$$b7
000491583 7001_ $$0P:(DE-H253)PIP1094798$$aSimancas, Adriana$$b8$$udesy
000491583 7001_ $$0P:(DE-H253)PIP1014417$$aStanitzki, Marcel$$b9
000491583 7001_ $$0B.Weinlader.1$$aWeinläder, Benjamin$$b10
000491583 8564_ $$uhttps://bib-pubdb1.desy.de/record/491583/files/2212.10248v1.pdf$$yRestricted
000491583 8564_ $$uhttps://bib-pubdb1.desy.de/record/491583/files/2212.10248v1.pdf?subformat=pdfa$$xpdfa$$yRestricted
000491583 909CO $$ooai:bib-pubdb1.desy.de:491583$$pVDB
000491583 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1031938$$aDeutsches Elektronen-Synchrotron$$b3$$kDESY
000491583 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1024990$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000491583 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1094798$$aDeutsches Elektronen-Synchrotron$$b8$$kDESY
000491583 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1014417$$aDeutsches Elektronen-Synchrotron$$b9$$kDESY
000491583 9131_ $$0G:(DE-HGF)POF4-622$$1G:(DE-HGF)POF4-620$$2G:(DE-HGF)POF4-600$$3G:(DE-HGF)POF4$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMatter and Technologies$$vDetector Technologies and Systems$$x0
000491583 9141_ $$y2023
000491583 915__ $$0StatID:(DE-HGF)0580$$2StatID$$aPublished
000491583 9201_ $$0I:(DE-H253)FTX-20210408$$kFTX$$lTechnol. zukünft. Teilchenph. Experim.$$x0
000491583 9201_ $$0I:(DE-H253)FHTestBeam-20150203$$kFHTestBeam$$lDetector RD at DESY Test beam$$x1
000491583 980__ $$apreprint
000491583 980__ $$aVDB
000491583 980__ $$aI:(DE-H253)FTX-20210408
000491583 980__ $$aI:(DE-H253)FHTestBeam-20150203
000491583 980__ $$aUNRESTRICTED