@INPROCEEDINGS{Wanzenberg:478500,
      author       = {Wanzenberg, Rainer and Bieler, Michael and Keil, Joachim
                      and Sahoo, Gajendra Kumar and Schaumann, Michaela},
      title        = {{PETRA} {III} {O}peration with {H}igh {A}vailability},
      journal      = {Journal of physics / Conference Series},
      volume       = {2380},
      number       = {1},
      issn         = {1742-6588},
      address      = {Bristol},
      publisher    = {IOP Publ.},
      reportid     = {PUBDB-2022-02603},
      pages        = {012002},
      year         = {2022},
      abstract     = {The Synchrotron Light Source PETRA III at DESY is one of
                      the most brilliant storage-ring based X-ray sources for
                      high-energy photons worldwide, which offers scientists
                      unique X-ray experiments in a wide range of fields since
                      2009. The light source is operated mainly in two operation
                      modes with 480 and 40 bunches at a beam energy of 6 GeV with
                      a maximum beam current of up to 120 mA. High reliability is
                      one of the key requirements for a synchrotron radiation
                      facility. The key performance indicators, availability and
                      mean time between failures (MTBF), could be significantly
                      improved during the operation periods of the last years. As
                      the final milestones of the extension project that started
                      in 2014, a new undulator was installed for the beamline P62
                      in the Paul P. Ewald hall in 2020, and a new dipole beamline
                      (P66) have been installed in the North East section of PETRA
                      III in 2021.},
      month         = {Mar},
      date          = {2022-03-28},
      organization  = {14th International Conference on
                       Synchrotron Radiation Instrumentation,
                       Hamburg (Germany), 28 Mar 2022 - 1 Apr
                       2022},
      cin          = {MPE / MPY / MBB},
      ddc          = {530},
      cid          = {I:(DE-H253)MPE-20120731 / I:(DE-H253)MPY-20120731 /
                      I:(DE-H253)MBB-20120731},
      pnm          = {621 - Accelerator Research and Development (POF4-621)},
      pid          = {G:(DE-HGF)POF4-621},
      experiment   = {EXP:(DE-H253)PETRAIII(machine)-20150101},
      typ          = {PUB:(DE-HGF)16 / PUB:(DE-HGF)8},
      doi          = {10.1088/1742-6596/2380/1/012002},
      url          = {https://bib-pubdb1.desy.de/record/478500},
}