% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INBOOK{McMahon:476343,
      author       = {McMahon, Malcolm I.},
      title        = {{S}ynchrotron and {FEL} {S}tudies of {M}atter at {H}igh
                      {P}ressures; {S}econd edition},
      address      = {Cham},
      publisher    = {Springer International Publishing},
      reportid     = {PUBDB-2022-01694},
      isbn         = {9783030232016},
      pages        = {1-40},
      year         = {2018},
      comment      = {Synchrotron Light Sources and Free-Electron Lasers /
                      Jaeschke, Eberhard (Editor) ; Cham : Springer International
                      Publishing, 2018, Chapter 67-1 ; ISBN: 978-3-319-04507-8 ;
                      doi:10.1007/978-3-319-04507-8},
      booktitle     = {Synchrotron Light Sources and
                       Free-Electron Lasers / Jaeschke,
                       Eberhard (Editor) ; Cham : Springer
                       International Publishing, 2018, Chapter
                       67-1 ; ISBN: 978-3-319-04507-8 ;
                       doi:10.1007/978-3-319-04507-8},
      abstract     = {Samples compressed to very high pressures are typically
                      very small or exist for only a very short period of time.
                      Researchers seeking to make x-ray studies of matter under
                      such conditions have therefore always sought access to the
                      brightest possible x-ray sources – synchrotrons – and,
                      more recently, x-ray FELs. In this chapter, after a brief
                      introduction and a short history of high-pressure science, I
                      describe the techniques used to compress matter to pressures
                      well above 1 million atmospheres (1 megabar or 100 GPa) both
                      statically and dynamically and then review how experiments
                      are conducted on such samples at both synchrotrons and
                      XFELs. I conclude with a discussion about the opportunities
                      afforded by the start-up of diffraction-limited synchrotrons
                      and the new European XFEL.},
      cin          = {DOOR ; HAS-User / FS-CFEL-1},
      ddc          = {539.735},
      cid          = {I:(DE-H253)HAS-User-20120731 /
                      I:(DE-H253)FS-CFEL-1-20120731},
      pnm          = {631 - Matter – Dynamics, Mechanisms and Control
                      (POF4-631) / 6G3 - PETRA III (DESY) (POF4-6G3)},
      pid          = {G:(DE-HGF)POF4-631 / G:(DE-HGF)POF4-6G3},
      experiment   = {EXP:(DE-H253)P-P02.2-20150101},
      typ          = {PUB:(DE-HGF)7},
      doi          = {10.1007/978-3-319-04507-8_67-1},
      url          = {https://bib-pubdb1.desy.de/record/476343},
}