% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@ARTICLE{Rivas:474569,
author = {Rivas, Daniel E. and Serkez, Svitozar and Baumann, Thomas
M. and Boll, Rebecca and Czwalinna, Marie Kristin and Dold,
Simon and de Fanis, Alberto and Gerasimova, Natalia and
Grychtol, Patrik and Lautenschlager, Björn and Lederer,
Maximilian and Jezynksi, Tomasz and Kane, Daniel and Mazza,
Tommaso and Meier, Joachim and Müller, Jost and Pallas,
Florent and Rompotis, Dimitrios and Schmidt, Philipp and
Schulz, Sebastian and Usenko, Sergey and Venkatesan, Sandhya
and Wang, Jinxiong and Meyer, Michael},
title = {{H}igh-temporal-{R}esolution {X}-ray {S}pectroscopy with
{F}ree-{E}lectron and {O}ptical {L}asers},
journal = {Optica},
volume = {9},
number = {4},
issn = {2334-2536},
address = {Washington, DC},
publisher = {OSA},
reportid = {PUBDB-2022-00873},
pages = {429 -},
year = {2022},
abstract = {Ultrafast X-ray spectroscopies require flexible X-ray
properties together with high temporal and spectral
resolution. Here, we demonstrate simultaneous sub-20 fs and
sub-eV resolutions for pump/probe experiments, without the
need for additional photon arrival-time monitors.},
cin = {MSK},
ddc = {620},
cid = {I:(DE-H253)MSK-20120731},
pnm = {621 - Accelerator Research and Development (POF4-621)},
pid = {G:(DE-HGF)POF4-621},
experiment = {EXP:(DE-H253)XFEL-SQS-20150101},
typ = {PUB:(DE-HGF)16},
UT = {WOS:000786174500014},
doi = {10.1364/OPTICA.454920},
url = {https://bib-pubdb1.desy.de/record/474569},
}