@TECHREPORT{Svidras:473367,
      author       = {Svidras, Henrikas and Roehrken, Markus and Bolz, Arthur and
                      Komarov, Ilya and wehle, simon and Tackmann, Kerstin},
      title        = {{M}easurement of the data to {MC} ratio of photon
                      reconstruction efficiency of the {B}elle {II} calorimeter
                      using radiative muon pair events},
      number       = {BELLE2-NOTE-PL-2021-008},
      reportid     = {PUBDB-2021-05692, BELLE2-NOTE-PL-2021-008},
      pages        = {7},
      year         = {2021},
      note         = {16 August 2021},
      abstract     = {This note presents photon detection eciency
                      data-to-simulation ratio distributions in the barrelregion
                      of the electromagnetic calorimeter of the Belle II detector
                      at the SuperKEKB asymmetricenergy electron-positron
                      collider. They are computed using 71:2 fb},
      cin          = {BELLE},
      cid          = {I:(DE-H253)BELLE-20210408},
      pnm          = {611 - Fundamental Particles and Forces (POF4-611)},
      pid          = {G:(DE-HGF)POF4-611},
      experiment   = {EXP:(DE-H253)BELLE-20150101},
      typ          = {PUB:(DE-HGF)29},
      doi          = {10.3204/PUBDB-2021-05692},
      url          = {https://bib-pubdb1.desy.de/record/473367},
}