% IMPORTANT: The following is UTF-8 encoded. This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@INPROCEEDINGS{Lorbeer:416814,
author = {Lorbeer, Bastian and Beutner, Bolko and Duhme, Hans Thomas
and Fröhlich, Lars and Lipka, Dirk and Nölle, Dirk},
title = {{E}nergy {B}eam {P}osition {M}onitor {B}utton {A}rray
{E}lectronics for the {E}uropean {XFEL}},
address = {Geneva, Switzerland},
publisher = {JACoW Publishing},
reportid = {PUBDB-2018-05180},
isbn = {978-3-95450-184-7},
pages = {1927-1928},
year = {2018},
abstract = {The European XFEL(X-Ray Free Electron Laser) at
DESY(Deutsches Elektronen-Synchrotron) in Hamburg/Schenefeld
started commissioning in early 2017. Before the pulsed
electron beam is accelerated to its final energy of 14 GeV,
the energy of the bunch can be compressed in three bunch
compression chicanes at 130 MeV, 700 MeV and 2400 MeV. The
vacuum chamber in these sections is tapered from 40 mm round
beam pipe to a 40 cm rectangular shaped vacuum section. A
custom made button array type of BPM(Beam position Monitor)
is installed in this section with 26 button electrode
feed-throughs. The analog and digital readout electronics
for this monitor and the first experience with the
calibration and operational aspects of this system are
presented in this poster.},
month = {Apr},
date = {2018-04-29},
organization = {9th International Particle Accelerator
Conference, Vancouver (Canada), 29 Apr
2018 - 4 May 2018},
cin = {MDI / MPY / MCS 1 / MDI 2 / MXL / MSK},
cid = {I:(DE-H253)MDI-20120806 / I:(DE-H253)MPY-20120731 /
$I:(DE-H253)MCS_1-20120731$ / $I:(DE-H253)MDI_2-20120731$ /
I:(DE-H253)MXL-20160301 / I:(DE-H253)MSK-20120731},
pnm = {6G13 - XFEL (POF3-622)},
pid = {G:(DE-HGF)POF3-6G13},
experiment = {EXP:(DE-H253)XFEL(machine)-20150101},
typ = {PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
doi = {10.18429/JACOW-IPAC2018-WEPAF049},
url = {https://bib-pubdb1.desy.de/record/416814},
}