% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INPROCEEDINGS{VilcinsCzvitkovits:408417,
      author       = {Vilcins-Czvitkovits, Silke and Bandke, Daniel and Holz,
                      Maximilian},
      title        = {{A} {N}ew {S}ealing {T}echnology for {H}igh {P}recision
                      {W}ide {O}pen {UHV} {V}acuum lange and {W}aveguide
                      {C}onnections with {M}etal {G}askets},
      reportid     = {PUBDB-2018-02850},
      year         = {2018},
      abstract     = {The European-XFEL X-Ray laser facility is located in
                      Hamburg. Since its commissioning in September 2017, this
                      large X-ray laser opens new research opportunities for
                      industrial users and scientists. For many beam diag-nostic
                      devices ultra-high vacuum components with high mechanical
                      precision and additional strict requirements on particle
                      cleanliness were produced. A vacuum chamber for the bunch
                      compressor (BC) with a cross section of 400 mm*40.5 mm made
                      of stainless steel blocks 1.4429 (316 LN) has been
                      installed. These chambers have inte-grated
                      flange-connections for large VATSEAL® gaskets. The
                      tolerances for these flanges are extremely tight to ensure
                      save vacuum tight sealing.This contribution will report of a
                      new technology for such large rectangular or other large
                      flange surfaces. Furthermore this contribution will compare
                      the present with this new technology. This new technology
                      can be used as well for other vacuum flange metals like
                      alumini-um or titanium. Using of this technology for
                      applications under special conditions, like particle free
                      applications due to the non-lubricated conditions, are
                      conceivable.},
      month         = {Jun},
      date          = {2018-06-25},
      organization  = {10th edition of the Mechanical
                       Engineering Design of Synchrotron
                       Radiation Equipment and
                       Instrumentation, Paris (France), 25 Jun
                       2018 - 29 Jun 2018},
      cin          = {MDI / ZEU-MECH1},
      cid          = {I:(DE-H253)MDI-20120806 / I:(DE-H253)ZEU-MECH1-20120731},
      pnm          = {631 - Accelerator R $\&$ D (POF3-631)},
      pid          = {G:(DE-HGF)POF3-631},
      experiment   = {EXP:(DE-H253)XFEL(machine)-20150101},
      typ          = {PUB:(DE-HGF)24},
      doi          = {10.3204/PUBDB-2018-02850},
      url          = {https://bib-pubdb1.desy.de/record/408417},
}