% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INPROCEEDINGS{Li:408361,
      author       = {Li, H. B. and Wong, H. T.},
      collaboration = {{TEXONO Collaboration}},
      title        = {{D}ark {M}atter {S}earches with sub-ke{V} {G}ermanium
                      {D}etector},
      address      = {Hamburg},
      publisher    = {Verlag Deutsches Elektronen-Synchrotron},
      reportid     = {PUBDB-2018-02814, DESY-PROC-2013-04},
      isbn         = {978-3-935702-83-6},
      series       = {DESY-PROC},
      pages        = {207-210},
      year         = {2013},
      comment      = {Li, H.B. "Dark Matter Searches with sub-keV Germanium
                      Detector" in Proceedings, 9th Patras Workshop on Axions,
                      WIMPs and WISPs (AXION-WIMP 2013) / Oberlack, Uwe, Sissol,
                      Pierre (eds.), 2013 ; AXION-WIMP 2013 : 9th Patras Workshop
                      on Axions, WIMPs and WISPs , 2013-06-23 - 2013-06-28, Mainz},
      booktitle     = {Li, H.B. "Dark Matter Searches with
                       sub-keV Germanium Detector" in
                       Proceedings, 9th Patras Workshop on
                       Axions, WIMPs and WISPs (AXION-WIMP
                       2013) / Oberlack, Uwe, Sissol, Pierre
                       (eds.), 2013 ; AXION-WIMP 2013 : 9th
                       Patras Workshop on Axions, WIMPs and
                       WISPs , 2013-06-23 - 2013-06-28, Mainz},
      abstract     = {We report new limits on spin-independent WIMP-nucleon
                      interaction cross-section using 39.5 kg-days of data taken
                      with a p-type point-contact germanium detector of 840 g
                      fi-ucial mass at the Kuo-Sheng Reactor Neutrino Laboratory.
                      Crucial to this study is the understanding of the selection
                      procedures and, in particular, the bulk-surface events
                      diff-entiation at the sub-keV range. The signal- retaining
                      and background-rejecting efficiencies were measured with
                      calibration gamma sources and a novel n-type point-contact
                      germa-nium detector. Part of the parameter space in
                      cross-section versus WIMP-mass implied by various
                      experiments is probed and excluded.},
      month         = {Jun},
      date          = {2013-06-24},
      organization  = {9th Patras Workshop on Axions, WIMPs
                       and WISPs, Mainz (Germany), 24 Jun 2013
                       - 28 Jun 2013},
      keywords     = {Hypothetisches Teilchen (gnd)},
      cin          = {L},
      cid          = {I:(DE-H253)L-20120731},
      pnm          = {899 - ohne Topic (POF3-899)},
      pid          = {G:(DE-HGF)POF3-899},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)29 / PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      doi          = {10.3204/DESY-PROC-2013-04/li_hau-bin},
      url          = {https://bib-pubdb1.desy.de/record/408361},
}