% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INPROCEEDINGS{Galan:408332,
      author       = {Galan, J. and Gerbier, G. and Giomataris, I. and
                      Papaevangelou, T. and Savvidis, I.},
      title        = {{E}xtending axions searches with a spherical {TPC}},
      address      = {Hamburg},
      publisher    = {Verlag Deutsches Elektronen-Synchrotron},
      reportid     = {PUBDB-2018-02785, DESY-PROC-2013-04},
      isbn         = {978-3-935702-83-6},
      series       = {DESY-PROC},
      pages        = {59-62},
      year         = {2013},
      comment      = {Galan, J. "Extending axions searches with a spherical TPC"
                      in Proceedings, 9th Patras Workshop on Axions, WIMPs and
                      WISPs (AXION-WIMP 2013) / Oberlack, Uwe, Sissol, Pierre
                      (eds.), 2013 ; AXION-WIMP 2013 : 9th Patras Workshop on
                      Axions, WIMPs and WISPs , 2013-06-23 - 2013-06-28, Mainz},
      booktitle     = {Galan, J. "Extending axions searches
                       with a spherical TPC" in Proceedings,
                       9th Patras Workshop on Axions, WIMPs
                       and WISPs (AXION-WIMP 2013) / Oberlack,
                       Uwe, Sissol, Pierre (eds.), 2013 ;
                       AXION-WIMP 2013 : 9th Patras Workshop
                       on Axions, WIMPs and WISPs , 2013-06-23
                       - 2013-06-28, Mainz},
      abstract     = {We present the prospects for detection of KK-axions using a
                      large volum spherical TPC through natural decay to two
                      gammas. The higher excited mass states of this axion model
                      allows to reach densities which could be detectable by this
                      method. We show the capability of this detector to detect
                      2-prong events coming from rest-mass axion decays and we
                      provide efficiencies obtained under some gas mixtures and
                      pressure conditions. The sensitivity limit of a future
                      experiment with existing detectors geometry has been
                      estimated for the case of zero background limit.},
      month         = {Jun},
      date          = {2013-06-24},
      organization  = {9th Patras Workshop on Axions, WIMPs
                       and WISPs, Mainz (Germany), 24 Jun 2013
                       - 28 Jun 2013},
      keywords     = {Hypothetisches Teilchen (gnd)},
      cin          = {L},
      cid          = {I:(DE-H253)L-20120731},
      pnm          = {899 - ohne Topic (POF3-899)},
      pid          = {G:(DE-HGF)POF3-899},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)29 / PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      doi          = {10.3204/DESY-PROC-2013-04/galan_javier},
      url          = {https://bib-pubdb1.desy.de/record/408332},
}