000395886 001__ 395886
000395886 005__ 20211110145247.0
000395886 0247_ $$2datacite_doi$$a10.3204/PUBDB-2017-12370
000395886 037__ $$aPUBDB-2017-12370
000395886 041__ $$aEnglish
000395886 1001_ $$0P:(DE-H253)PIP1003055$$aWittenburg, Kay$$b0$$eCorresponding author$$udesy
000395886 1112_ $$a3rd European Workshop on Beam Diagnostics and Instrumentation for Particle Accelerators$$cFrascati$$d1997-10-12 - 1997-10-14$$gDIPAC97$$wItaly
000395886 245__ $$aA Non Destructive Way to measure Betatron Mismatch at Injection
000395886 260__ $$aFrascati$$bFrascati$$c1997
000395886 300__ $$a159-161
000395886 3367_ $$2ORCID$$aCONFERENCE_PAPER
000395886 3367_ $$033$$2EndNote$$aConference Paper
000395886 3367_ $$2BibTeX$$aINPROCEEDINGS
000395886 3367_ $$2DRIVER$$aconferenceObject
000395886 3367_ $$2DataCite$$aOutput Types/Conference Paper
000395886 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1513241487_18921
000395886 3367_ $$0PUB:(DE-HGF)7$$2PUB:(DE-HGF)$$aContribution to a book$$mcontb
000395886 4900_ $$aLNF-INFN, SIS-Pubbl., 1997.$$vLNF-97/048 (IR)
000395886 500__ $$aNICHT POF III, zu alt
000395886 520__ $$aBetatron mismatch between a chain of proton (or ion) accelerators blows up the emittance of the beam. Following the ideas of Ref. 1, we study the use of Residual Gas Ionization ProfileMonitors to measure this mismatch without disturbing the beam. A turn by turn readout can be performed by electrical or video readout. The sensitivity of the monitor is adjustable over a few decades by a local gas bump. First studies at DESY III will be presented.
000395886 536__ $$0G:(DE-HGF)POF3-631$$a631 - Accelerator R & D (POF3-631)$$cPOF3-631$$fPOF III$$x0
000395886 693__ $$0EXP:(DE-H253)HERA(machine)-20150101$$1EXP:(DE-588)4159571-3$$5EXP:(DE-H253)HERA(machine)-20150101$$aHERA$$eFacility (machine) HERA$$x0
000395886 773__ $$vLNF-97/048 (IR)
000395886 8564_ $$uhttp://adweb.desy.de/mdi/downloads/pcd.pdf
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.pdf$$yOpenAccess
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.gif?subformat=icon$$xicon$$yOpenAccess
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000395886 8564_ $$uhttps://bib-pubdb1.desy.de/record/395886/files/A%20Non%20Destructive%20Way%20to%20measure%20Betatron%20Mismatch%20at%20Injection.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000395886 909CO $$ooai:bib-pubdb1.desy.de:395886$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000395886 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1003055$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000395886 9131_ $$0G:(DE-HGF)POF3-631$$1G:(DE-HGF)POF3-630$$2G:(DE-HGF)POF3-600$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vAccelerator R & D$$x0
000395886 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000395886 9201_ $$0I:(DE-H253)MDI-20120806$$kMDI$$lDiagnose und Instrumentierung$$x0
000395886 980__ $$acontrib
000395886 980__ $$aVDB
000395886 980__ $$aUNRESTRICTED
000395886 980__ $$acontb
000395886 980__ $$aI:(DE-H253)MDI-20120806
000395886 9801_ $$aFullTexts