@INPROCEEDINGS{Boeckmann:395417,
author = {Boeckmann, Torsten and Bozhko, Yury and Gaj, Wawrzyniec and
Halczynski, Pawel and Petersen, Bernd and Putselyk, Sergiy
and Schnautz, Tobias and Sienkiewicz, Michal and
Swierblewski, Jacek},
title = {{S}erial testing of {XFEL} cryomodules: results of the
cryogenic heat load measurements},
reportid = {PUBDB-2017-12091},
pages = {7},
year = {2017},
abstract = {The European X-ray Free Electron Laser (XFEL) is in
operation at DESY. The superconducting XFEL linac will
produce pulsed electron beam at an energy of 17.5 GeV. The
linac consists of 768 superconducting niobium 1.3 GHz nine
cell cavities and 96 superconducting magnet packages
assembled in 96 cryomodules. Each cryomodule is 12 m long
and includes a 2 K helium II bath circuit for the cavities
and 5/8 and 40/80 K thermal radiation shields. Before being
installed in the XFEL linac tunnel all cryomodules were
tested in the Accelerator Module Test Facility (AMTF ) . In
this paper methods and results of static and dynamic heat
load measurements of all XFEL cryomodules are reported. A
comparison with first integral heat load measurements in the
XFEL linac is given},
month = {Jul},
date = {2017-07-09},
organization = {2017 Cryogenic Engineering Conference
and International Cryogenic Materials
Conference, Madison (USA), 9 Jul 2017 -
13 Jul 2017},
cin = {MKS1 / MKS2 / MKS},
cid = {I:(DE-H253)MKS1-20210408 / I:(DE-H253)MKS2-20210408 /
I:(DE-H253)MKS-20120806},
pnm = {6G13 - XFEL (POF3-622)},
pid = {G:(DE-HGF)POF3-6G13},
experiment = {EXP:(DE-H253)XFEL(machine)-20150101},
typ = {PUB:(DE-HGF)8},
doi = {10.3204/PUBDB-2017-12091},
url = {https://bib-pubdb1.desy.de/record/395417},
}