000395417 001__ 395417
000395417 005__ 20211110145207.0
000395417 0247_ $$2datacite_doi$$a10.3204/PUBDB-2017-12091
000395417 037__ $$aPUBDB-2017-12091
000395417 041__ $$aEnglish
000395417 1001_ $$0P:(DE-H253)PIP1002947$$aBoeckmann, Torsten$$b0$$udesy
000395417 1112_ $$a2017 Cryogenic Engineering Conference and International Cryogenic Materials Conference$$cMadison$$d2017-07-09 - 2017-07-13$$wUSA
000395417 245__ $$aSerial testing of XFEL cryomodules: results of the cryogenic heat load measurements
000395417 260__ $$c2017
000395417 300__ $$a7
000395417 3367_ $$2ORCID$$aCONFERENCE_PAPER
000395417 3367_ $$033$$2EndNote$$aConference Paper
000395417 3367_ $$2BibTeX$$aINPROCEEDINGS
000395417 3367_ $$2DRIVER$$aconferenceObject
000395417 3367_ $$2DataCite$$aOutput Types/Conference Paper
000395417 3367_ $$0PUB:(DE-HGF)8$$2PUB:(DE-HGF)$$aContribution to a conference proceedings$$bcontrib$$mcontrib$$s1511276289_31447
000395417 520__ $$aThe European X-ray Free Electron Laser (XFEL) is in operation at DESY. The superconducting XFEL linac will produce pulsed electron beam at an energy of 17.5 GeV. The linac consists of 768 superconducting niobium 1.3 GHz nine cell cavities and 96 superconducting magnet packages assembled in 96 cryomodules. Each cryomodule is 12 m long and includes a 2 K helium II bath circuit for the cavities and 5/8 and 40/80 K thermal radiation shields. Before being installed in the XFEL linac tunnel all cryomodules were tested in the Accelerator Module Test Facility (AMTF ) . In this paper methods and results of static and dynamic heat load measurements of all XFEL cryomodules are reported. A comparison with first integral heat load measurements in the XFEL linac is given
000395417 536__ $$0G:(DE-HGF)POF3-6G13$$a6G13 - XFEL (POF3-622)$$cPOF3-622$$fPOF III$$x0
000395417 693__ $$0EXP:(DE-H253)XFEL(machine)-20150101$$1EXP:(DE-H253)XFEL-20150101$$5EXP:(DE-H253)XFEL(machine)-20150101$$aXFEL$$eFacility (machine) XFEL$$x0
000395417 7001_ $$0P:(DE-H253)PIP1000493$$aBozhko, Yury$$b1$$eCorresponding author$$udesy
000395417 7001_ $$0P:(DE-H253)PIP1019600$$aGaj, Wawrzyniec$$b2
000395417 7001_ $$0P:(DE-H253)PIP1022014$$aHalczynski, Pawel$$b3
000395417 7001_ $$0P:(DE-H253)PIP1003167$$aPetersen, Bernd$$b4$$udesy
000395417 7001_ $$0P:(DE-HGF)0$$aPutselyk, Sergiy$$b5
000395417 7001_ $$0P:(DE-H253)PIP1005320$$aSchnautz, Tobias$$b6$$udesy
000395417 7001_ $$0P:(DE-H253)PIP1013632$$aSienkiewicz, Michal$$b7
000395417 7001_ $$0P:(DE-H253)PIP1014278$$aSwierblewski, Jacek$$b8
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.pdf$$yOpenAccess
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.gif?subformat=icon$$xicon$$yOpenAccess
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000395417 8564_ $$uhttps://bib-pubdb1.desy.de/record/395417/files/Serial%20testing%20of%20XFEL%20cryomodules%3A%20results%20of%20the%20cryogenic%20heat%20load%20measurements.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000395417 909CO $$ooai:bib-pubdb1.desy.de:395417$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000395417 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1002947$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000395417 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1000493$$aDeutsches Elektronen-Synchrotron$$b1$$kDESY
000395417 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$aInstytut Fizyki Jadrowej (IFJ), Polskiej Akademii Nauk (PAN), 31-342 Krakow, Poland $$b2
000395417 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1022014$$aInstytut Fizyki Jadrowej (IFJ), Polskiej Akademii Nauk (PAN), 31-342 Krakow, Poland $$b3
000395417 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1003167$$aDeutsches Elektronen-Synchrotron$$b4$$kDESY
000395417 9101_ $$0I:(DE-HGF)0$$6P:(DE-HGF)0$$aFerchau Engineering GmbH, Butzweilerhof-Allee 4, 50829, Köln, Germany $$b5
000395417 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1005320$$aDeutsches Elektronen-Synchrotron$$b6$$kDESY
000395417 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1013632$$aInstytut Fizyki Jadrowej (IFJ), Polskiej Akademii Nauk (PAN), 31-342 Krakow, Poland $$b7
000395417 9101_ $$0I:(DE-HGF)0$$6P:(DE-H253)PIP1014278$$aInstytut Fizyki Jadrowej (IFJ), Polskiej Akademii Nauk (PAN), 31-342 Krakow, Poland $$b8
000395417 9131_ $$0G:(DE-HGF)POF3-622$$1G:(DE-HGF)POF3-620$$2G:(DE-HGF)POF3-600$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$9G:(DE-HGF)POF3-6G13$$aDE-HGF$$bForschungsbereich Materie$$lVon Materie zu Materialien und Leben$$vFacility topic: Research on Matter with Brilliant Light Sources$$x0
000395417 9141_ $$y2017
000395417 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000395417 9201_ $$0I:(DE-H253)MKS1-20210408$$kMKS1$$lKryogenik$$x0
000395417 9201_ $$0I:(DE-H253)MKS2-20210408$$kMKS2$$lKryokontrollen$$x1
000395417 9201_ $$0I:(DE-H253)MKS-20120806$$kMKS$$lKryogenik und Supraleitung$$x2
000395417 980__ $$acontrib
000395417 980__ $$aVDB
000395417 980__ $$aUNRESTRICTED
000395417 980__ $$aI:(DE-H253)MKS1-20210408
000395417 980__ $$aI:(DE-H253)MKS2-20210408
000395417 980__ $$aI:(DE-H253)MKS-20120806
000395417 9801_ $$aFullTexts