@ARTICLE{Nichols:324653,
author = {Nichols, M. C. and Kinney, J. H. and Johnson, Q. C. and
Saroyan, R. A. and Bonse, U. and Nusshardt, R. and Pahl, R.},
title = {{S}ynchrotron microtomography of supported catalysts},
journal = {Review of scientific instruments},
volume = {60},
number = {7},
issn = {1089-7623},
address = {[S.l.]},
publisher = {American Institute of Physics},
reportid = {PUBDB-2017-04832},
pages = {2475 - 2477},
year = {1989},
note = {HASYLAB},
abstract = {Synchrotron microtomography is a new technique which is
capable of elemental, chemical, and structure sensitive
imaging in three dimensions at resolutions better than 15
μm. This paper describes the first application of this new
technique to the investigation of the morphology and
elemental distribution of a supported catalyst. Using this
new tool it was possible to obtain three‐dimensional
information from regions of the catalyst away from the
vicinity of the damaged surface region of the sample. The
technique allows the use of both computed tomographic (CT)
cross sections as well as the development of a
three‐dimensional rendering of elements in a material,
each of which allows visualization of different areas that
would go unnoticed in normal radiographic or CT
investigations.},