001     320875
005     20211110141334.0
024 7 _ |a arXiv:1703.05738
|2 arXiv
024 7 _ |a 10.3204/PUBDB-2017-02151
|2 datacite_doi
024 7 _ |a inspire:1517781
|2 inspire
037 _ _ |a PUBDB-2017-02151
041 _ _ |a English
088 1 _ |a arXiv:1703.05738
088 _ _ |a arXiv:1703.05738
|2 arXiv
100 1 _ |a Schuetz, Anne
|0 P:(DE-H253)PIP1020267
|b 0
|e Corresponding author
|u desy
111 2 _ |a International Workshop on Future Linear Colliders 2016
|g LCWS2016
|c Morioka
|d 2016-12-05 - 2016-12-09
|w Japan
245 _ _ |a A Study of the Impact of Muons from the Beam Delivery System on the SiD Performance
260 _ _ |c 2017
300 _ _ |a 15
336 7 _ |a CONFERENCE_PAPER
|2 ORCID
336 7 _ |a Conference Paper
|0 33
|2 EndNote
336 7 _ |a INPROCEEDINGS
|2 BibTeX
336 7 _ |a conferenceObject
|2 DRIVER
336 7 _ |a Report
|0 PUB:(DE-HGF)29
|2 PUB:(DE-HGF)
|m report
336 7 _ |a Output Types/Conference Paper
|2 DataCite
336 7 _ |a Contribution to a conference proceedings
|b contrib
|m contrib
|0 PUB:(DE-HGF)8
|s 1494323241_26463
|2 PUB:(DE-HGF)
520 _ _ |a To suppress the muon background arising from the Beam Delivery System (BDS) of the International Linear Collider (ILC), and to hinder it from reaching the interaction region, two different shielding scenarios are under discussion: five cylindrical muon spoilers with or without an additional magnetized shielding wall. Due to cost and safety issues, the scenario preferred by the Machine-Detector-Interface (MDI) group is to omit the shielding wall, although omitting it also has disadvantages. To support the decision making for the muon shielding, the impact of the muons from the two different shielding scenarios was studied in a full Geant4 detector simulation of the SiD detector, one of two proposed detectors for the ILC. Input to this study is the muon background created by the beam traveling through the BDS, which was simulated with MUCARLO.
536 _ _ |0 G:(DE-HGF)POF3-611
|c POF3-611
|f POF III
|x 0
|a 611 - Fundamental Particles and Forces (POF3-611)
588 _ _ |a Dataset connected to INSPIRE
650 _ 7 |a muon: background
|2 INSPIRE
650 _ 7 |a muon: shielding
|2 INSPIRE
650 _ 7 |a SiD
|2 INSPIRE
650 _ 7 |a GEANT
|2 INSPIRE
650 _ 7 |a numerical calculations: Monte Carlo
|2 INSPIRE
650 _ 7 |a safety
|2 INSPIRE
650 _ 7 |a costs
|2 INSPIRE
693 _ _ |a ILC
|e Facility (machine) ILC
|1 EXP:(DE-H253)ILC-20150101
|0 EXP:(DE-H253)ILC(machine)-20150101
|5 EXP:(DE-H253)ILC(machine)-20150101
|x 0
700 1 _ |a Keller, Lewis
|0 P:(DE-HGF)0
|b 1
700 1 _ |a White, Glen
|0 P:(DE-HGF)0
|b 2
856 4 _ |y OpenAccess
|u https://bib-pubdb1.desy.de/record/320875/files/1703.05738.pdf
856 4 _ |y OpenAccess
|x icon
|u https://bib-pubdb1.desy.de/record/320875/files/1703.05738.gif?subformat=icon
856 4 _ |y OpenAccess
|x icon-1440
|u https://bib-pubdb1.desy.de/record/320875/files/1703.05738.jpg?subformat=icon-1440
856 4 _ |y OpenAccess
|x icon-180
|u https://bib-pubdb1.desy.de/record/320875/files/1703.05738.jpg?subformat=icon-180
856 4 _ |y OpenAccess
|x icon-640
|u https://bib-pubdb1.desy.de/record/320875/files/1703.05738.jpg?subformat=icon-640
909 C O |o oai:bib-pubdb1.desy.de:320875
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 0
|6 P:(DE-H253)PIP1020267
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Materie und Universum
|1 G:(DE-HGF)POF3-610
|0 G:(DE-HGF)POF3-611
|2 G:(DE-HGF)POF3-600
|x 0
|4 G:(DE-HGF)POF
|v Fundamental Particles and Forces
|3 G:(DE-HGF)POF3
914 1 _ |y 2017
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
920 1 _ |0 I:(DE-H253)FLA-20120731
|k FLA
|l Forschung Linear Accelerator
|x 0
920 1 _ |0 I:(DE-H253)KIT-20130928
|k KIT
|l externe Institute im Bereich Photon Science
|x 1
920 1 _ |0 I:(DE-H253)SLAC-20170401
|k SLAC
|l Stanford Linear Accelerator Center
|x 2
980 _ _ |a contrib
980 _ _ |a VDB
980 _ _ |a UNRESTRICTED
980 _ _ |a report
980 _ _ |a I:(DE-H253)FLA-20120731
980 _ _ |a I:(DE-H253)KIT-20130928
980 _ _ |a I:(DE-H253)SLAC-20170401
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21