TY - CONF AU - Brinkmann, Arne AU - Ziegler, Joerg TI - Dry-Ice Cleaning of RF-Structures at DESY M1 - PUBDB-2016-05804 SP - 4 PY - 2016 AB - Dry-Ice cleaning is today a well established cleaning method in matters of reducing harmful dark current and field emission in copper RF structureslike RF-Guns such as for the European XFEL, FLASH and REGAE. This led to the idea to clean longer RF-structures, in particular 3GHz transverse deflecting structures for the European XFEL. We developed a cleaning device with the possibility to clean up to 2 m long structures in horizontal position with an inner diameter of not more than 40 mm. Furthermore this device also allows to clean 9-cell TESLA-type Nb-cavities as well. A report of the technical layout and results of RF-tests will be given T2 - 28th Linear Accelerator Conference CY - 25 Sep 2016 - 30 Sep 2016, East Lansing (USA) Y2 - 25 Sep 2016 - 30 Sep 2016 M2 - East Lansing, USA LB - PUB:(DE-HGF)8 DO - DOI:10.3204/PUBDB-2016-05804 UR - https://bib-pubdb1.desy.de/record/315368 ER -