TY  - JOUR
AU  - Perez Benito, R.
AU  - Khaneft, Dmitry
AU  - O Connor, C.
AU  - Capozza, Luigi
AU  - Diefenbach, Juergen
AU  - Glaeser, B.
AU  - Ma, Yue
AU  - Maas, Frank
AU  - Rodriguez Pineiro, David
TI  - Design and Performance of a Lead Fluoride Detector as a Luminosity Monitor
JO  - Nuclear instruments & methods in physics research / A
VL  - 826
SN  - 0168-9002
CY  - Amsterdam
PB  - North-Holland Publ. Co.
M1  - PUBDB-2016-02975
SP  - 6 - 14
PY  - 2015
N1  - Elsevier B.V.
AB  - Precise luminosity measurements for the OLYMPUS two-photon exchange experiment at DESY were performed by counting scattering events with alternating beams of electrons and positrons incident on atomic electrons in a gaseous hydrogen target. Final products of MΕller, Bhabha, and pair annihilation interactions were observed using a pair of lead fluoride (PbF<sub>2</sub>) Cherenkov calorimeters with custom housings and electronics, adapted from a system used by the A4 parity violation experiment at MAMI. This paper describes the design, calibration, and operation of these detectors. An explanation of the Monte Carlo methods used to simulate the physical processes involved both at the scattering vertices and in the detector apparatus is also included.
LB  - PUB:(DE-HGF)16
UR  - <Go to ISI:>//WOS:000376887100002
DO  - DOI:10.1016/j.nima.2016.04.071
UR  - https://bib-pubdb1.desy.de/record/301918
ER  -