@INPROCEEDINGS{Maiano:292558,
      author       = {Maiano, C. G. and Albrecht, C. and Bospflug, R. and
                      Branlard, J. and Delfs, T. and Eschke, J. and Hoffmann, F.
                      and Hüning, M. and Jensch, K. and Jonas, R. and Klos, R.
                      and Kostin, D. and Maschmann, W. and Matheisen, A. and
                      Mavrič, U. and Möller, W.-D. and Müller, C. and Mueller,
                      K. and Petersen, Bernd and Pierini, P. and Rothenburg, J.
                      and Sawlanski, O. and Schmökel, M. and Sulimov, Alexey and
                      Vogel, E. and Butkowski, Lukasz and Pierini, Paolo and
                      Bosotti, A. and Moretti, M. and Paparella, R. and Sertore,
                      D. and Harms, E. and Pivovarov, Sergey and Montiel, R. and
                      Goessel, Andre},
      title        = {{H}orizontal {RF} {T}est of a {F}ully {E}quipped 3.9 {GH}z
                      {C}avity for the {E}uropean {XFEL} in the {DESY} {AMTF}},
      reportid     = {PUBDB-2015-06207},
      isbn         = {978-3-95450-178-6},
      pages        = {1-5},
      year         = {2015},
      note         = {Pre-Press Release},
      abstract     = {In order to validate the cavity package concept before the
                      module preparation for the European XFEL Injector, one 3.9
                      GHz cavity, complete with magnetic shielding, power coupler
                      and frequency tuner was tested in a specially designed
                      single cavity cryomodule in one of the caves of the DESY
                      Accelerator Module Test Facility (AMTF). The cavity was
                      tested in high power pulsed operation up to the quench limit
                      of 24 MV/m, above the vertical test qualifications and all
                      subsystems under test (coupler, tuner, waveguide tuners,
                      LLRF system) were qualified to design performances.},
      month         = {Sep},
      date          = {2015-09-13},
      organization  = {17th International Conference on RF
                       Superconductivity, Whistler (Canada),
                       13 Sep 2015 - 18 Sep 2015},
      cin          = {MSK / MKS1 / MPY / MVS / MCS 2 / MHF-sl / MIN / MKS3 /
                      MKS2},
      cid          = {I:(DE-H253)MSK-20120731 / I:(DE-H253)MKS1-20210408 /
                      I:(DE-H253)MPY-20120731 / I:(DE-H253)MVS-20120731 /
                      $I:(DE-H253)MCS_2-20120731$ / I:(DE-H253)MHF-sl-20120731 /
                      I:(DE-H253)MIN-20120731 / I:(DE-H253)MKS3-20210408 /
                      I:(DE-H253)MKS2-20210408},
      pnm          = {6G13 - XFEL (POF3-622)},
      pid          = {G:(DE-HGF)POF3-6G13},
      experiment   = {EXP:(DE-H253)XFEL(machine)-20150101},
      typ          = {PUB:(DE-HGF)8},
      url          = {https://bib-pubdb1.desy.de/record/292558},
}