001     275875
005     20250730113433.0
024 7 _ |a 10.1063/1.4921220
|2 doi
024 7 _ |a WOS:000360649200011
|2 WOS
024 7 _ |a altmetric:3997437
|2 altmetric
024 7 _ |a pmid:26798808
|2 pmid
024 7 _ |a openalex:W274788909
|2 openalex
037 _ _ |a PUBDB-2015-04292
041 _ _ |a English
082 _ _ |a 530
100 1 _ |a Chavas, Leonard
|0 P:(DE-H253)PIP1020851
|b 0
|e Corresponding author
245 _ _ |a Possibilities for serial femtosecond crystallography sample delivery at future light sources
260 _ _ |a Melville, NY
|c 2015
|b AIP Publishing LLC
336 7 _ |a article
|2 DRIVER
336 7 _ |a Output Types/Journal article
|2 DataCite
336 7 _ |a Journal Article
|b journal
|m journal
|0 PUB:(DE-HGF)16
|s 1480921385_32671
|2 PUB:(DE-HGF)
336 7 _ |a ARTICLE
|2 BibTeX
336 7 _ |a JOURNAL_ARTICLE
|2 ORCID
336 7 _ |a Journal Article
|0 0
|2 EndNote
520 _ _ |a Serial femtosecond crystallography (SFX) uses X-ray pulses from free-electron laser(FEL) sources that can outrun radiation damage and thereby overcome long-standing limits in the structure determination of macromolecular crystals. Intense X-rayFEL pulses of sufficiently short duration allow the collection of damage-free data at room temperature and give the opportunity to study irreversible time-resolved events. SFX may open the way to determine the structure of biological molecules that fail to crystallize readily into large well-diffracting crystals. Taking advantage of FELs with high pulse repetition rates could lead to short measurement times of just minutes. Automated delivery of sample suspensions for SFX experiments could potentially give rise to a much higher rate of obtaining complete measurements than at today's third generation synchrotron radiation facilities, as no crystal alignment or complex robotic motions are required. This capability will also open up extensive time-resolved structural studies. New challenges arise from the resulting high rate of data collection, and in providing reliable sample delivery. Various developments for fully automated high-throughput SFX experiments are being considered for evaluation, including new implementations for a reliable yet flexible sample environment setup. Here, we review the different methods developed so far that best achieve sample delivery for X-rayFEL experiments and present some considerations towards the goal of high-throughput structure determination with X-rayFELs.
536 _ _ |a 6215 - Soft Matter, Health and Life Sciences (POF3-621)
|0 G:(DE-HGF)POF3-6215
|c POF3-621
|f POF III
|x 0
536 _ _ |a 05E13GU1 - Entwicklung eines "Serial Femtosecond Crystallography (SFX)"-Messtandes am Europäischen Elektronenlaser XFEL (BMBF-05E13GU1)
|0 G:(DE-H253)BMBF-05E13GU1
|c BMBF-05E13GU1
|x 1
536 _ _ |a 05K13GU7 - Test eines "Serial Femtosecond Crystallography (SFX)"-Messtandes am Europäischen Elektronenlaser XFEL (BMBF-05K13GU7)
|0 G:(DE-H253)BMBF-05K13GU7
|c BMBF-05K13GU7
|x 2
588 _ _ |a Dataset connected to CrossRef
693 _ _ |0 EXP:(DE-H253)CFEL-Exp-20150101
|5 EXP:(DE-H253)CFEL-Exp-20150101
|e Experiments at CFEL
|x 0
700 1 _ |a Gumprecht, L.
|0 P:(DE-H253)PIP1002488
|b 1
700 1 _ |a Chapman, H. N.
|0 P:(DE-H253)PIP1006324
|b 2
|e Corresponding author
773 _ _ |a 10.1063/1.4921220
|g Vol. 2, no. 4, p. 041709 -
|0 PERI:(DE-600)2758684-4
|n 4
|p 041709 -
|t Structural dynamics
|v 2
|y 2015
|x 2329-7778
856 4 _ |u https://bib-pubdb1.desy.de/record/275875/files/10.1063_1.4921220Chavas.pdf
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/275875/files/10.1063_1.4921220Chavas.gif?subformat=icon
|x icon
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/275875/files/10.1063_1.4921220Chavas.jpg?subformat=icon-1440
|x icon-1440
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/275875/files/10.1063_1.4921220Chavas.jpg?subformat=icon-180
|x icon-180
|y OpenAccess
856 4 _ |u https://bib-pubdb1.desy.de/record/275875/files/10.1063_1.4921220Chavas.jpg?subformat=icon-640
|x icon-640
|y OpenAccess
909 C O |o oai:bib-pubdb1.desy.de:275875
|p openaire
|p open_access
|p VDB
|p driver
|p dnbdelivery
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 0
|6 P:(DE-H253)PIP1020851
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 1
|6 P:(DE-H253)PIP1002488
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 1
|6 P:(DE-H253)PIP1002488
910 1 _ |a Deutsches Elektronen-Synchrotron
|0 I:(DE-588b)2008985-5
|k DESY
|b 2
|6 P:(DE-H253)PIP1006324
910 1 _ |a Centre for Free-Electron Laser Science
|0 I:(DE-H253)_CFEL-20120731
|k CFEL
|b 2
|6 P:(DE-H253)PIP1006324
913 1 _ |a DE-HGF
|b Forschungsbereich Materie
|l Von Materie zu Materialien und Leben
|1 G:(DE-HGF)POF3-620
|0 G:(DE-HGF)POF3-621
|2 G:(DE-HGF)POF3-600
|v In-house research on the structure, dynamics and function of matter
|9 G:(DE-HGF)POF3-6215
|x 0
|4 G:(DE-HGF)POF
|3 G:(DE-HGF)POF3
914 1 _ |y 2015
915 _ _ |a Creative Commons Attribution CC BY 3.0
|0 LIC:(DE-HGF)CCBY3
|2 HGFVOC
915 _ _ |a OpenAccess
|0 StatID:(DE-HGF)0510
|2 StatID
915 _ _ |a DBCoverage
|0 StatID:(DE-HGF)0200
|2 StatID
|b SCOPUS
920 1 _ |0 I:(DE-H253)FS-CFEL-1-20120731
|k FS-CFEL-1
|l CFEL-Coherent X-Ray Imaging
|x 0
980 _ _ |a journal
980 _ _ |a VDB
980 _ _ |a I:(DE-H253)FS-CFEL-1-20120731
980 _ _ |a UNRESTRICTED
980 1 _ |a UNRESTRICTED
980 1 _ |a FullTexts


LibraryCollectionCLSMajorCLSMinorLanguageAuthor
Marc 21