000208060 001__ 208060
000208060 005__ 20211110130523.0
000208060 0247_ $$2datacite_doi$$a10.3204/DESY-THESIS-2015-009
000208060 037__ $$aPUBDB-2015-01537
000208060 041__ $$aEnglish
000208060 0881_ $$aDESY-THESIS-2015-009
000208060 088__ $$2DESY$$aDESY-THESIS-2015-009
000208060 1001_ $$0P:(DE-H253)PIP1023364$$aHuebner, Lars$$b0$$eCorresponding Author$$gmale$$udesy
000208060 245__ $$aTests and measurements with a thermal VXD mock-up for BELLE II$$f2014-10-13 - 2015-03-13
000208060 260__ $$aHamburg$$bVerlag Deutsches Elektronen-Synchrotron$$c2015
000208060 300__ $$ai-55
000208060 3367_ $$2DRIVER$$abachelorThesis
000208060 3367_ $$02$$2EndNote$$aThesis
000208060 3367_ $$2DataCite$$aOutput Types/Supervised Student Publication
000208060 3367_ $$0PUB:(DE-HGF)2$$2PUB:(DE-HGF)$$aBachelor Thesis$$bbachelor$$mbachelor$$s1435049009_7269
000208060 3367_ $$0PUB:(DE-HGF)29$$2PUB:(DE-HGF)$$aReport$$mreport
000208060 3367_ $$2BibTeX$$aMASTERSTHESIS
000208060 3367_ $$2ORCID$$aSUPERVISED_STUDENT_PUBLICATION
000208060 4900_ $$0PERI:(DE-600)1437131-5$$aDESY-THESIS$$x1435-8085
000208060 502__ $$aUniversität Hamburg, Bachelorarbeit, 2015$$bBA$$cUniversität Hamburg$$d2015
000208060 520__ $$aAs part of the Belle detector upgrade, located at the KEK in Tsukuba, Japan, a CO2 cooling system willbe added. Using new detector components, which are easily damageable or influenced by heat, makethis step necessary. Particularly the next to the beam pipe located PXD is strained by high thermal loadand therefore requires cooling. The CDC needs a constant temperature for precise measurements, butit could be influenced by heat from the SVD. Knowledge about the heat generation and distribution isneeded before assembling the full detector. A mock-up of the innermost parts of the detector and aCO2 cooling system is under construction at DESY in Hamburg, Germany, to gather such knowledge.The mock-up should be able to emulate the thermal properties of the final detector. Within the scopeof this bachelor’s thesis, the outermost VXD Layer 6 was studied in a flat arrangement. Focus layon the heat dissipation at the sensors and on pressure drop measurements of the cooling pipe. It wasinvestigated whether the applied heat load can be suciently lead away and how large the pressuredrop is along the experiment line. Despite cooling was applied, a remarkable rise in temperature wasobserved. However, the unfavorable position of the thermistors make reliable quantitative statementsof the sensor dummies’ temperatures impossible. The pressure drop was determined, but is of limitedaccuracy due to large uncertainties. Further investigations have to be made with a better set-up.
000208060 536__ $$0G:(DE-HGF)POF3-632$$a632 - Detector technology and systems (POF3-632)$$cPOF3-632$$fPOF III$$x0
000208060 650_7 $$0V:(DE-588b)4276536-5$$2GND$$aUnveröffentlichte Hochschulschrift$$xBachelorarbeit
000208060 693__ $$0EXP:(DE-MLZ)NOSPEC-20140101$$5EXP:(DE-MLZ)NOSPEC-20140101$$eNo specific instrument$$x0
000208060 773__ $$y2015
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/Thesis.pdf$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.ps$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/Thesis.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/Thesis.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/Thesis.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/Thesis.pdf?subformat=pdfa$$xpdfa$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.gif?subformat=icon$$xicon$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.jpg?subformat=icon-1440$$xicon-1440$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.jpg?subformat=icon-180$$xicon-180$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.jpg?subformat=icon-640$$xicon-640$$yOpenAccess
000208060 8564_ $$uhttps://bib-pubdb1.desy.de/record/208060/files/desy-thesis-15-009.title.jpg?subformat=icon-700$$xicon-700$$yOpenAccess
000208060 909CO $$ooai:bib-pubdb1.desy.de:208060$$pdnbdelivery$$pdriver$$pVDB$$popen_access$$popenaire
000208060 9101_ $$0I:(DE-588b)2008985-5$$6P:(DE-H253)PIP1023364$$aDeutsches Elektronen-Synchrotron$$b0$$kDESY
000208060 9130_ $$0G:(DE-HGF)POF2-513$$1G:(DE-HGF)POF2-510$$2G:(DE-HGF)POF2-500$$aDE-HGF$$bStruktur der Materie$$lElementarteilchenphysik$$vPreparation for a future lepton collider$$x0
000208060 9131_ $$0G:(DE-HGF)POF3-632$$1G:(DE-HGF)POF3-630$$2G:(DE-HGF)POF3-600$$3G:(DE-HGF)POF3$$4G:(DE-HGF)POF$$aDE-HGF$$bForschungsbereich Materie$$lMaterie und Technologie$$vDetector technology and systems$$x0
000208060 9141_ $$y2015
000208060 915__ $$0StatID:(DE-HGF)0510$$2StatID$$aOpenAccess
000208060 920__ $$lyes
000208060 9201_ $$0I:(DE-H253)Belle-20160426$$kBelle$$lbeauftragt von FH1$$x0
000208060 980__ $$abachelor
000208060 980__ $$aVDB
000208060 980__ $$aUNRESTRICTED
000208060 980__ $$aFullTexts
000208060 980__ $$areport
000208060 980__ $$aI:(DE-H253)Belle-20160426
000208060 9801_ $$aFullTexts