% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@INPROCEEDINGS{Pennicard:207221,
      author       = {Pennicard, D. and Smoljanin, S. and Sheviakov, I. and Xia,
                      Qingqing and Rothkirch, A. and Yu, Y. and Struth, B. and
                      Hirsemann, H. and Graafsma, H.},
      title        = {{H}igh-{S}peed {R}eadout of {H}igh-{Z} {P}ixel {D}etectors
                      with the {LAMBDA} {D}etector},
      journal      = {Journal of Instrumentation},
      volume       = {9},
      number       = {12},
      issn         = {1748-0221},
      address      = {London},
      publisher    = {Inst. of Physics},
      reportid     = {PUBDB-2015-01204},
      pages        = {C12014},
      year         = {2014},
      note         = {OA},
      abstract     = {High-frame-rate X-ray pixel detectors make it possible to
                      perform time-resolved experiments at synchrotron beamlines,
                      and to make better use of these sources by shortening
                      experiment times. LAMBDA is a photon-counting hybrid pixel
                      detector based on the Medipix3 chip, designed to combine a
                      small pixel size of 55 μm, a large tileable module design,
                      high speed, and compatibility with ``high-Z sensors for hard
                      X-ray detection. This technical paper focuses on LAMBDAs
                      high-speed-readout functionality, which allows a frame rate
                      of 2000 frames per second with no deadtime between
                      successive images. This takes advantage of the Medipix3
                      chips ``continuous read-write function and highly
                      parallelised readout. The readout electronics serialise this
                      data and send it back to a server PC over two 10 Gigabit
                      Ethernet links. The server PC controls the detector and
                      receives, processes and stores the data using software
                      designed for the Tango control system. As a demonstration of
                      high-speed readout of a high-Z sensor, a GaAs LAMBDA
                      detector was used to make a high-speed X-ray video of a
                      computer fan.},
      month         = {Sep},
      date          = {2014-09-07},
      organization  = {10th International Conference on
                       Position Sensitive Detectors,
                       University of Surrey (UK), 7 Sep 2014 -
                       12 Sep 2014},
      keywords     = {semiconductor detector: pixel (INSPIRE) / electronics:
                      readout (INSPIRE) / electronics: communications (INSPIRE) /
                      X-ray: detector (INSPIRE) / programming (INSPIRE) / time
                      resolution (INSPIRE) / gallium (INSPIRE) / arsenic
                      (INSPIRE)},
      cin          = {FS-DS / FS-EC / FEA},
      ddc          = {610},
      cid          = {I:(DE-H253)FS-DS-20120731 / I:(DE-H253)FS-EC-20120731 /
                      I:(DE-H253)FEA-20120731},
      pnm          = {541 - Photons (POF2-541)},
      pid          = {G:(DE-HGF)POF2-541},
      experiment   = {EXP:(DE-MLZ)NOSPEC-20140101},
      typ          = {PUB:(DE-HGF)8 / PUB:(DE-HGF)16},
      UT           = {WOS:000345859200014},
      doi          = {10.1088/1748-0221/9/12/C12014},
      url          = {https://bib-pubdb1.desy.de/record/207221},
}